ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 456-460 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Theory ; Linearity between peak width and retention data ; Evaluation of GC equipment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The linearity of the relationship between σT,t2 and (1 + k)2 is studied with the view of using it for the evaluation of GC equipment. Based on appropriate analytical expressions it is concluded that in general this relationship is not linear and that practical procedures for column evaluation should be developed that take this non-linearity into account.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 124-128 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Series-coupled chemically differing columns ; Fundamental studies on the properties for basic theory started ; Retention time and separation efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Basic expressions are derived for both the retention time and the effective separation factor in serially coupled GC columns. The retention time is determined by two main parameters. The first is the fractional time spent by an unretarded solute in each column which, in turn, is determined by the relative column lengths and flow velocities through each column. The second parameter is the relative mass distribution coefficient of a particular solute in each column; a variable that can be adjusted by changing the relative temperatures of the columns. The expression for the effective separation factor relates the measured separation factor for the series combination to the separation factors on the individual columns, the fractional time spent by an unretarded peak in each column, as well as the relative values of the mass distribution coefficients of a particular solute on the different columns.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 385-392 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Theory of band broadening ; Regression methods in column evaluation abt concept ; Possible aid in assessing coating efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the approach to the developement of a practical procedure for the evaluation of band broadening properties of gas capillary columns, the expression for the variance of a solute band is cast in a dimensionless form. This expression supplies the basis for a valid bench mark for column evaluation. Experimental results demonstrate the applicability of the method.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...