ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 2019-04-23
    Description: The FRESCO (Fast Retrieval Scheme for Clouds from the Oxygen A band) algorithm is a simple, fast and robust algorithm used to retrieve cloud information in operational satellite data processing. It has been applied to GOME-1 (Global Ozone Monitoring Experiment), SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography), GOME-2 and more recently to TROPOMI (Tropospheric Monitoring Instrument). FRESCO retrieves effective cloud fraction and cloud pressure from measurements in the oxygen A band around 761 nm. In this paper, we propose a new version of the algorithm, called FRESCO-B, which is based on measurements in the oxygen B band around 687 nm. Such a method is interesting for vegetated surfaces where the surface albedo is much lower in the B band than in the A band, which limits the ground contribution to the top-of-atmosphere reflectances. In this study we first perform retrieval simulations. These show that the retrieved cloud pressures from FRESCO-B and FRESCO differ only between −10 and +10 hPa, except for high, thin clouds over vegetation where the difference is larger (about +15 to +30 hPa), with FRESCO-B yielding higher pressure. Next, inter-comparison between FRESCO-B and FRESCO retrievals over 1 month of GOME-2B data reveals that the effective cloud fractions retrieved in the O2 A and B bands are very similar (mean difference of 0.003), while the cloud pressures show a mean difference of 11.5 hPa, with FRESCO-B retrieving higher pressures than FRESCO. This agrees with the simulations and is partly due to deeper photon penetrations of the O2 B band in clouds compared to the O2 A-band photons and partly due to the surface albedo bias in FRESCO. Finally, validation with ground-based measurements shows that the FRESCO-B cloud pressure represents an altitude within the cloud boundaries for clouds that are not too far from the Lambertian reflector model, which occurs in about 50 % of the cases.
    Print ISSN: 1867-1381
    Electronic ISSN: 1867-8548
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2018-12-10
    Description: The FRESCO (Fast Retrieval Scheme for Clouds from the Oxygen A-band) algorithm is a simple, fast and robust algorithm used to retrieve cloud information in operational satellite data processing. It has been applied to GOME-1, SCIAMACHY, GOME-2 and more recently to TROPOMI. FRESCO retrieves effective cloud fraction and cloud pressure from measurements in the oxygen A-band around 761 nm. In this paper, we propose a new version of the algorithm, called FRESCO-B, which is based on measurements in the oxygen B-band around 687 nm. Such a method is interesting for vegetated surfaces where the surface albedo is much lower in the B-band than in the A-band, which limits the ground contribution to the top-of-atmosphere reflectances. In this study we first perform retrieval simulations. These show that the retrieved cloud pressures from FRESCO-B and FRESCO differ only between −10 hPa and +10 hPa, except for high thin clouds over vegetation where the difference is larger, about +15 to +30 hPa, with FRESCO-B yielding higher pressures. Next, inter-comparison between FRESCO-B and FRESCO retrievals over one month of GOME-2B data reveals that the effective cloud fractions retrieved in the O2 A and B bands are very similar (mean difference of 0.003) while the cloud pressures show a mean difference of 11.5 hPa, with FRESCO-B retrieving higher pressures than FRESCO. This agrees with the simulations and is partly due to deeper photons penetrations of O2 B-band in clouds as compared to the O2 A-band photons, and partly due to the surface albedo bias in FRESCO. Finally, validation with ground-based measurements shows that the FRESCO-B cloud pressure represents an altitude within the cloud boundaries for clouds that are not too far from the Lambertian reflector model, which occurs in about 50 % of the cases.
    Electronic ISSN: 1867-8610
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2016-10-11
    Description: Information content analyses on cloud top altitude (CTOP) and geometrical thickness (CGT) from multi-angular A-band measurements in the case of monolayer homogeneous clouds are conducted. In the framework of future multi-angular radiometer development, we compared the potential performances of the 3MI (Multi-viewing, Multi-channel and Multi-polarization Imaging) instrument developed by EUMETSAT, which is an extension of POLDER/PARASOL instrument and MSPI (Multiangle SpectroPolarimetric Imager) developed by NASA's Jet Propulsion Laboratory. Quantitative information content estimates were realized for thin, moderately opaque and opaque clouds for different surface albedo and viewing geometry configurations. Analyses show that retrieval of CTOP is possible with a high accuracy in most of the cases investigated. Retrieval of CGT is also possible for optically thick clouds above a black surface, at least when CGT 〉 1–2 km and for thin clouds for CGT 〉 2–3 km. However, for intermediate optical thicknesses (COT ≃ 4), we show that the retrieval of CGT is not simultaneously possible with CTOP. A comparison between 3MI and MSPI shows a higher information content for MSPI's measurements, traceable to a thinner filter inside the oxygen A-band, yielding higher signal-to-noise ratio for absorption estimation. Cases of cloud scenes above bright surfaces are more complex but it is shown that the retrieval of CTOP remains possible in almost all situations while the information content on CGT appears to be insufficient in many cases, particularly for COT 
    Print ISSN: 1867-1381
    Electronic ISSN: 1867-8548
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...