ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 7 (1973), S. 235-249 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Since the accidental rediscovery of the endosteal implant by Formaggini in the late 1940's, the field has witnessed a tremendous evolution in theory and clinical application. Chercheve, in his efforts to improve on earlier spiral designs, proposed several theories on the relationship of the metallic endosteal implant to its osseous environment. Some of the problems he experienced still have not been overcome in our present designs.The development of the blade implant marked a true advancement in endosteal design. This implant proved to be much more functional and reliable than the spiral concept; however, it too had certain disadvantages which became obvious after a relatively short period of clinical trial. The anchor endosteal implant was developed as a result of efforts to correct the various problems associated with the blade.Preliminary animal research using both anchor and blade implants was begun. Four dogs had each type of implant inserted in edentulous areas. The animals were sacrificed four months post insertion for histologic examination. More sophisticated animal implant studies are being performed at the Brookdale Hospital Medical Center.Clinical evaluation of the anchor implant over a 3-year period has been very encouraging. Results have indicated a higher level of clinical success than previously achieved with blade or spiral designs.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 385-390 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This paper presents a review of 338 metallic endosteal oral implants of six designs that had been in situ for periods of up to seven years as observed by members of the Brookdale Group. Of the 338 impervious alloplastic endosteal implants studied, none but the endodontic endosteal implant demonstrated positive long range findings. It would appear that the eventual demise of endosteal implants is predictable on a basis of time.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource