Publication Date:
2016-06-07
Description:
A fuze assembly, which consists of three major parts, nose, collar and sleeve, was designed to survive severe transverse impact giving a maximum base acceleration of 20.000 G. It is shown that hoop failure occurred in the collar after the impact. They also showed that by bonding the collar to the nose, the collar was able to survive the same impact. To find out the effectiveness of the bonding quantitatively, axisymmetric solid elements TRAPAX and TRIAAX were used in modelling the fuze and direct transient analysis was performed. The dynamic stresses in selected elements on the bonded and unbonded collars were compared. The peak hoop stresses in the unbonded collar were found to be up to three times higher than those in the bonded collar. The NASTRAN results explained the observed hoop failure in the unbonded collar. In addition, static and eigenvalue runs were performed as checks on the models prior to the transient runs. The use of the MPCAX cards and the existence and contributors of the calculated first several nearly identical natural frequencies are addressed.
Keywords:
STRUCTURAL MECHANICS
Type:
COSMIC 13th NASTRAN (R) Users' Colloq.; p 431-452
Format:
application/pdf
Permalink