ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0197-8462
    Keywords: magnetic fields ; exposure system ; stray fields ; Merritt coils ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Exposure systems that provide good magnetic field uniformity, minimum stray fields, and minimal heating, vibration, and hum, as well as capability for true sham exposure in which current flows in the coils, are needed to determine rigorously the biological effects of weak magnetic fields. Designs based on acrylic polymer coil support structures and twisted pair bifilary coil windings were employed to fabricate several different systems for the exposure of laboratory animals and cell cultures to magnetic fields. These systems exhibit excellent performance characteristics in terms of exposure field uniformity, stray field containment, and exposure field cancellation in the sham exposure mode. A custom-written computer program was used to determine the best arrangement for coils with regard to field uniformity in the exposure volume and stray field containment. For in vivo exposures, modules were made up of four Merritt four-coil sets, built into a single structure and positioned to form an octapole with fields directed in the horizontal plane. For in vitro applications, two different coil configurations were selected to produce the vertical fields required. A quadrupole system, comprising modules consisting of two Merritt four-coil sets arranged side by side to limit stray fields, was built as a prototype. In the second configuration, one Merritt four-coil set was positioned inside the other to form a concentric coil set. In both in vitro systems, exposure chambers were connected to remote commercial incubators in order to reduce ambient magnetic fields in the exposure volume. An active field cancellation circuit was developed for reducing ambient AC magnetic fields in the in vitro sham exposure chamber, when necessary. These design and fabrication approaches provide systems that offer uniform field exposures and excellent stray field containment when needed and are portable, washable, and relatively inexpensive. © 1994 Wiley-Liss, Inc.This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 18 (1997), S. 478-490 
    ISSN: 0197-8462
    Keywords: organ dosimetry ; low-frequency magnetic induction ; numerical modelling ; FDTD calculations ; impedance method ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effects of human body model resolution on computed electric fields induced by 60 Hz uniform magnetic fields are investigated. A recently-developed scalar potential finite difference code for low-frequency electromagnetic computations is used to model induction in two anatomically realistic human body models. The first model consists of 204 290 cubic voxels with 7.2-mm edges, while the second comprises 1 639 146 cubic voxels with 3.6-mm edges. Calculations on the lower-resolution model using, for example, the finite difference time domain or impedance methods, push the capabilities of workstations. The scalar method, in contrast, can handle the higher-resolution model using comparable resources. The results are given in terms of average and maximum electric field intensities and current density magnitudes in selected tissues and organs. Although the lower-resolution model provides generally acceptable results, there are important differences that make the added computational burden of the higher-resolution calculations worthwhile. In particular, the higher-resolution modelling generally predicts peak electric fields intensities and current density magnitudes that are slightly higher than those computed using the lower-resolution modelling. The differences can be quite large for small organs such as glands. Bioelectromagnetics 18:478-490, 1997. © 1997 Wiley-Liss, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1999-01-01
    Print ISSN: 0031-9155
    Electronic ISSN: 1361-6560
    Topics: Biology , Medicine , Physics
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 1997-12-01
    Print ISSN: 0031-9155
    Electronic ISSN: 1361-6560
    Topics: Biology , Medicine , Physics
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...