ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 1960-01-01
    Print ISSN: 0026-3672
    Electronic ISSN: 1436-5073
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1959-11-01
    Print ISSN: 0026-3672
    Electronic ISSN: 1436-5073
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1963-09-01
    Print ISSN: 0026-3672
    Electronic ISSN: 1436-5073
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 1929-02-19
    Print ISSN: 0863-1786
    Topics: Chemistry and Pharmacology
    Published by Wiley
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 47 (1959), S. 835-840 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary In dependence on a method published bySawarow and his associates, a new simplified modification is given of the indirect complexometric determination of phosphate, which avoids the tedious isolation of the phosphate precipitated as magnesium ammonium phosphate by means of excess magnesium chloride. It was found that the excess of magnesium chloride can be titrated accurately in 50% ethanol solution, even in the presence of the precipitate, by complexone with eriochrome black T as indicator, since the magnesium ammonium phosphate is practically insoluble in complexone in this medium. The method is intended particularly for the determination of phosphate in connection with theSchöniger combustion procedure.
    Abstract: Résumé Sur la base d'une méthode publiée parSawarow et ses collaborateurs l'auteur communique une nouvelle modification simple de la détermination complexométrique indirecte des phosphates qui permet d'éviter les complications de l'isolement du phosphate en le précipitant sous forme de phosphate ammoniaco -magnésien par un excès de chlorure de magnésium. Il a été établi que l'excès de chlorure de magnésium pouvait être dosé en retour avec une grande précision, par le complexon, en présence de noir ériochrome T et du précipité dans une solution éthanolique à 50%; le phosphate ammoniacomagnésien est en effet pratiquement insoluble dans le complexon dans un tel milieu. La méthode a été particulièrement étudiée pour son application au dosage des phosphates après combustion par la méthode deSchöniger.
    Notes: Zusammenfassung In Anlehnung an eine von Sawarow8 und Mitarbeitern veröffentlichte Methode wird eine neue einfachere Modifikation der indirekten komplexometrischen Bestimmung von Phosphat mitgeteilt, die die umständliche Isolierung des mit überschüssigem Magnesiumchlorid als Magnesiumammoniumphosphat gefällten Phosphats umgeht. Es wurde gefunden, daß der Magnesiumchloridüberschuß in 50%iger äthanolischer Lösung auch in Gegenwart des Niederschlages sehr genau mit Komplexon gegen Eriochromschwarz T zurücktitriert werden kann, da Magnesium-ammoniumphosphat in diesem Medium in Komplexon praktisch unlöslich ist. Die Methode ist besonders zur Phosphatbestimmung im Anschluß an die Verbrennung nachSchöniger gedacht.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 51 (1963), S. 1094-1108 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The flask method ofSchöniger on the semimicro scale with samples from 20–50 mg has been found excellent for the determination of heteroelements in organic materials and mixtures in commercial practice. Tested procedures are given for determining Cl, Br, S, P. On the basis of numerous routine analyses, the reproducibility of these methods has been statistically studied under the conditions of industrial practice. The standard deviations for the determination of Cl and Br were found to be almost independent of the content of the sample, while they increased with rising content in the case of S and P. The error of the mean value of a duplicate determination in all four cases remained within the limit ± 0,3% absolute with a certainty of 95%. Thus the methods satisfy the demands of industry in most cases. Suitable tolerance procedures for supervising the methods and analytical findings are advised for the analytical practice. The study shows that without additional experimental expenditure it is possible to obtain statistically assured bases for the appraisal of analytical methods and findings from the routine analyses of an industrial laboratory.
    Abstract: Résumé La méthode utilisant la fiole deSchöniger a fait ses preuves dans l'industrie pour le dosage des hétéro-éléments dans les substances organiques et dans les mélanges, à l'échelle semimicro, avec une prise d'essai de 20–50 mg. On communique des modes opératoires éprouvés pour le dosage de Cl, Br, S et P. On a étudié statistiquement la reproductibilité de ces méthodes dans les conditions de la pratique industrielle, en se servant d'un grand nombre d'analyses en série. Les déviations standard pour le dosage du chlore et du brome s'avèrent comme pratiquement indépendantes de la teneur de l'échantillon, alors qu'elles augmentent dans le cas du soufre et du phosphore pour des teneurs croissantes. Pour les quatres dosages, l'erreur sur la valeur moyenne de deux déterminations reste comprise dans les limites de ± 0,3%, avec une limite de confiance de 95%. Dans la plupart des cas, les méthodes suffisent ainsi aux exigences de l'industrie. Du point de vue pratique de l'analyse on recommande les prescriptions de tolérance convenant au contrôle des méthodes et des résultats d'analyse. L'expérience montre qu'il est aussi possible, sans un effort éxpérimental supplémentaire, d'acquérir des appuis statistiquement sûrs à partir des analyses en série d'un laboratoire industriel, pour juger des méthodes et des résultats d'analyse.
    Notes: Zusammenfassung Zur Bestimmung von Heteroelementen in organischen Stoffen und Stoffgemischen in der Industrie hat sich die Kolbenmethode nachSchöniger im Halbmikromaßstab mit 20 bis 50 mg Einwaage sehr gut bewährt. Für die Bestimmung von Cl, Br, S und P werden erprobte Arbeitsvorschriften mitgeteilt. An Hand einer größeren Zahl von Routineanalysen wird die Reproduzierbarkeit dieser Methoden unter den Bedingungen der Industriepraxis statistisch untersucht. Die Standardabweichungen für die Bestimmung von Cl und Br erwiesen sich als praktisch unabhängig vom Gehalt der Probe, während sie bei S und P mit wachsendem Gehalt ansteigen. Bei allen vier Bestimmungen bleibt der Fehler des Mittelwertes einer Doppelbestimmung mit 95% Sicherheit innerhalb der Grenze ± 0,3% absolut. Damit genügen die Methoden in den meisten Fällen den Ansprüchen der Industrie. Für die analytische Praxis werden geeignete Toleranzvorschriften zur Überwachung der Methoden und Analysenergebnisse empfohlen. Die Untersuchung zeigt, daß es auch ohne zusätzlichen experimentellen Aufwand möglich ist, aus den Routineanalysen eines Industrielaboratoriums statistisch gesicherte Unterlagen zur Beurteilung von Analysenmethoden und -ergebnissen zu gewinnen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 48 (1960), S. 54-57 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary By means of the halogen determination on the semi-micro scale, it is shown that the Schöniger procedure can be used also on liquid substances if a simple modification is employed. The method fails only when the halogen content is very high.
    Abstract: Résumé Des exemples de semi microdosages des halogènes par la technique de Schöniger montrent qu'une simple modification permet de l'appliquer également à des substances volatiles. Elle n'est mise en échec que pour les substances à très haute teneur en halogènes.
    Notes: Zusammenfassung Am Beispiel der Halogenbestimmung im Halbmikromaßstab wird gezeigt, daß sich das Schöniger-Verfahren durch eine einfache Modifikation auch auf flüssige Substanzen anwenden läßt. Nur bei sehr hohem Halogengehalt versagt die Methode.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 179 (1929), S. 113-124 
    ISSN: 0863-1786
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...