ISSN:
1089-7623
Source:
AIP Digital Archive
Topics:
Physics
,
Electrical Engineering, Measurement and Control Technology
Notes:
Ions from this plasma are self-extracting with energies of 0.1 to 100 keV, the extraction potential being one of the desired observables. The charge/mass (z/μ, μ is mass in AMU) separation is provided by a static magnetic field (B⋅L=1280 G cm, FWHM=14 mm) located 5 cm from the linear (1−d) detector. Displacement along the detector axis is thus proportional to z/μ(1/v). The detector is a gold cathode MCP with a fast (sub-ns) phosphor. The phosphor output is coupled into a streak camera (typical sweep 8.5 or 24 μs total) through a coherent fiber bundle. Streak images are grabbed with a 14-bit CCD. The signature of any specific ion is a straight line of slope proportional to z/μ. Since there are usually more than one charge state of a given ion, integer multiple slopes appear. Thus z and m can be found. Absolute calibration is taken from the slope of the proton streak, which is always present with our plasmas. While providing the same information as a Thomson parabola, the straight line images are easier to extract information from and offer resolution with less energy dependence. By providing mass and time of flight information, the product of z⋅Te can be determined unambiguously during the hydrodynamic acceleration of the plasma. © 1995 American Institute of Physics.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1063/1.1146404
Permalink