Publication Date:
2019-07-13
Description:
The structures assembly model (SAM) was installed, and wind tunnel systems were checked out. The first run, with hydrogen cooling and SAM inserted in the wind tunnel stream (M = 7.7, P sub TOTAL = 900 psia, T sub TOTAL = 2500 deg R), was accomplished. The condition of the SAM after the run was satisfactory, with no visible signs or data indications of overheating or overloading.
Keywords:
PROPULSION SYSTEMS
Type:
NASA-CR-112056
,
AP-70-6939
,
ITDR-15
Format:
application/pdf
Permalink