ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Physiology 54 (1992), S. 135-152 
    ISSN: 0066-4278
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Medicine , Biology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Entomology 33 (1988), S. 39-58 
    ISSN: 0066-4170
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Biology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of comparative physiology 170 (1992), S. 729-738 
    ISSN: 1432-1351
    Keywords: Phototransduction ; Light adaptation ; Photon Insect vision ; Shunting conductance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The response of a locust, Locusta migratoria, photoreceptor to a simultaneous pair of dim flashes is smaller than the sum of the responses to the individual component flashes, even when the photon absorption sites are separated by a distance of 120 μm, which should prevent them from interacting biochemically. A similar depression is observed when a flash is paired with a depolarizing current instead of a second flash, irrespecive of whether the flash response precedes or follows the current response. These results indicate that the sublinear summation is caused by the activation of a voltage-activated shunting conductance. This conductance is not blocked by low intracellular concentrations of tetraethylammonium chloride, and is therefore different from the conductance which causes the decrease of the receptor's step response from transient to steady-state.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European biophysics journal 20 (1991), S. 65-69 
    ISSN: 1432-1017
    Keywords: Airway epithelium ; Asthma ; Apical membrane ; Ion channel kinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract The single channel inside-out patch clamp technique was used to characterize ion channels in the apical membranes of ragweed-sensitized and control canine tracheal epithelial cells maintained in primary culture. Patches were obtained from single isolated cells or from cells at the edges of confluent sheets. A new type of chloride channel was seen in sensitized cells but not in control cells. The channel showed inward rectification in symmetric chloride solutions with conductance varying from 95 pS to 52 pS over the range of −60 mV to 60 mV membrane potential. Channel gating was voltage dependent with maximal opening at about −30 mV Kinetic analysis showed that distributions of closed and open times could both be well fitted by the sums of three exponential components. Rate constants for transitions between the states of a linear kinetic model were calculated, with only one rate being significantly voltage dependent. The possible significance of this channel is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1017
    Keywords: Chloride channel ; Epithelium ; Ion permeation ; Mole fraction ; Liposomes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract Anion-selective channels from apical membranes of cultured CFPAC-1 cells were isolated and incorporated into giant liposomes for patch clamp recording. Liposomes were formed from L-α-lecithin by a dehydration-hydration method. Ion channels were characterized using the excised inside-out patch clamp configuration. The most commonly observed anion channels were similar to those observed in native epithelial tissues. The linear 20 pS Cl channel had the halide permeability sequence Cl− 〉 I− ≥ Br− 〉 F−, and showed anomalous mole-fraction behavior in solutions containing different proportions of Cl− and F−, ions. The autwardly rectifying Cl− channel had the halide permeability sequence I− 〉 Br− 〉 Cl− 〉 F−, and also showed anomalous molefraction behavior, indicating that both these channels probably contain multi-ion pores. The third, voltage-dependent anion channel showed at least five different substrates, had a conductance of 390 pS in the main state, and showed two types of kinetics, fast (openings and closings 〈 1 ms), and slow (openings and closings 〉 1 s). The channel was seen more frequently after reconstitution into giant liposomes than in intact cells. It was not selective amongst the halides, and there was no deviation from a linear dependence of relative current on molar fractions, indicating relatively simple permeation through the pore. Differences in halide permeabilities suggest that different anion channels may be related to different membrane proteins. Comparison with the chloride channel proteins isolated biochemically from epithelial cell membranes is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 8 (1971), S. 165-171 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Summary Spectral analysis provides powerful techniques for describing the lower order moments of a stochastic process and interactions between two or more stochastic processes. A major problem in the application of spectral analysis to neuronal spike trains is how to obtain equispaced samples of the spike trains which will give unbiased and alias-free spectral estimates. Various sampling methods, which treat the spike train as a continuous signal, a point process and as a series of Dirac delta-functions, are reviewed and their limitations discussed. A new sampling technique, which gives unbiased and alias-free estimates, is described. This technique treats the spike train as a series of delta functions and generates samples by digital filtering. Implementation of this technique on a small computer is simple and virtually on-line.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 22 (1976), S. 33-38 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Abstract Two types of sensillum have previously been described in the trochanteral hair plate of the cockroach with differences in physical size, extracellularly recorded impulse amplitude and response to displacement. We have now examined the dynamic behaviour of the two types of sesillum in response to sinusoidal and random displacements. Type I sensilla have a frequency threshold of about 6 Hz, below which there is no response to sinusoidal displacement. Above the frequency threshold they behave as velocity sensors with a 90° phase lead of response over displacement and increasing response with increasing frequency. Type II sensilla have no detectable frequency threshold and behave as position sensors at low frequencies. With increasing frequency they display a phase lead over the stimulus but it nerver exceeds about 60°. Random stimulation followed by spectral analysis of the input-output relations give similar descriptions to the sinusoidal results except that low frequency position sensitivity is revealed in the Type I sensilla. The coherence function for both types of sensillum is low, indicating that the linear frequency response functions are poor approximations to the total behaviour of the sensilla. Earlier investigations of these receptors in a range of insects suggested that they are primarily involved in the control of joint positions during very slow movements. However, the present results, together with other recent work, indicates that they are also important in the control of rapid movements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 27 (1977), S. 229-233 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Abstract In order to understand the significance of a regular photoreceptor mosaic we quantify the effect of deviations from regularity. Such deviations are shown to cause a deterioration in the quality of the image at the photoreceptor level because of image demodulation and image distortion. Consequently, a regular receptor array is necessary for extracting all of the spatial information available in the retinal image.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 32 (1979), S. 115-123 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Abstract The static and dynamic characteristics of phototransduction were studied in photoreceptors of the compound eye of the fly Phormia regina (Calliphoridae) using a green light emitting diode driven by a controlled current source. The LED provides sufficiently intense light to investigate the behaviour of the receptors over about half of the dark adapted range of the response versus log intensity curve. The effects of constant adapting light intensities upon the step response and upon the frequency response and coherence functions were examined. Using both methods the effect of light adaptation upon receptor sensitivity can be closely approximated by a similar linear dependence of log sensitivity upon log adapting intensity. However, there was no reliably detectable effect of light adaptation upon the time constant of the response over the range of adapting intensities used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 49 (1984), S. 169-174 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Abstract The behaviour of the space-clamped Hodgkin-Huxley model has been studied using bandlimited white noise (0–50 Hz) as the input membrane current and taking the output as a point process in time given by the peaks of the action potentials. The frequency response and coherence functions were measured by use of the Fourier transform and digital filtering of the spike train. The results obtained are in good agreement with those already published for the simple integrator and leaky integrator models of neuronal encoding, as well as the earlier studies on the response of the Hodgkin-Huxley model to steady currents. In addition, the threshold of the model to sinusoidal membrane currents has been measured as a function of frequency over the range of 0.1–100 Hz. This shows a relatively constant level up to 2 Hz and then a clear minimum at 60 Hz, in agreement with measured thresholds of squid axons. These results are discussed in terms of the possible contributions of action potential encoding mechanisms to the frequency responses and sinusoidal thresholds which have been measured for rapidly adapting receptors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...