Electronic Resource
[S.l.]
:
American Institute of Physics (AIP)
Review of Scientific Instruments
73 (2002), S. 2171-2174
ISSN:
1089-7623
Source:
AIP Digital Archive
Topics:
Physics
,
Electrical Engineering, Measurement and Control Technology
Notes:
This article reports on the frequency stability measurement system based upon the dual-mixer time-difference scheme working at 10 MHz with 1 Hz beat note. The principle of the system is reviewed, the design approach is described, and the experimental results are presented. The measurement system shows a stability of 5.6×10−14/τ (Allan deviation) and a temperature sensitivity of some picoseconds per Kelvin. An approach to reduce crosstalk problems has been tested. © 2002 American Institute of Physics.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1063/1.1464654
Permalink
|