ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    International journal of immunogenetics 15 (1988), S. 0 
    ISSN: 1744-313X
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Biologie , Medizin
    Notizen: We report here haplotype frequencies for class I (HLA-A, B), class III (HLA-DR) and class III (Bf) gene products of the major histocompatibility complex (MHC) of man. As in other studies (Bertrams & Baur, 1979; Grange et al., 1981), we have chosen to document all families typed for HLA antigens and Bf phenotypes irrespective of ascertainment. We obtained 1,094 haplotypes from 304 families resident in the North West of England, of which 34·1% had been fully typed for HLA-A,B,DR and Bf polymorphisms. We have been able to find both positive and negative linkage disequilibria for two and three locus haplotypes and have listed the most commonly occuring four locus haplotypes. Our data confirms the position of the complement group between HLA-B and HLA-DR, and we have looked for evidence of segregation distortion of MHC haplotypes.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [s.l.] : Nature Publishing Group
    Nature 196 (1962), S. 1315-1315 
    ISSN: 1476-4687
    Quelle: Nature Archives 1869 - 2009
    Thema: Biologie , Chemie und Pharmazie , Medizin , Allgemeine Naturwissenschaft , Physik
    Notizen: [Auszug] We saponified crude cottonseed oil by mixing it with alcoholic potassium hydroxide and allowing the reaction to proceed overnight at room temperature. The fatty acids obtained after acidification were dissolved in acetone, and a fraction soluble at - 60 was obtained. Further fractionations were ...
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Bulletin of environmental contamination and toxicology 57 (1996), S. 575 -581 
    ISSN: 1432-0800
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Energietechnik , Medizin
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Journal of materials science 5 (1994), S. 387-392 
    ISSN: 1573-4838
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: The abrasive wear behaviour of several orthopaedic bearing materials was characterized for fully conformal, reciprocating sliding contact against ultra-high molecular weight polyethylene (UHMWPE). The bearing surfaces investigated were nitrogen ion implanted Ti−6Al−4V, TiN coated Ti−6Al−4V, Ti−6Al−4V, F-799 Co−Cr−Mo, yttria-stabilized zirconia and a Zr−2.5Nb alloy with a zirconia ceramic surface. The third-body debris was introduced as either Ti−6Al−4V particles or oxidized titanium powder (black debris). The wear tests were performed in deionized water with the third-body debris entrapped between the UHMWPE and the hard bearing surface. Surface profilometry measurements, scanning electron microscopy (SEM) and optical microscopy showed the severity of damage to the hard bearing surfaces to increase with decreasing hardness. The abrasion damage to the UHMWPE increased as the roughness of the opposing, hard bearing surface increased. Surface profilometry and energy dispersive spectroscopy (EDS) also showed oxidized titanium (black debris) to form an adherent transfer layer on all of the hard bearing surfaces. Nitrogen ion implantation of Ti−6Al−4V was ineffective in reducing wear of both the Ti−6Al−4V substrate and the UHMWPE. Solid yttria-stabilized zirconia and zirconia-coated Zr−2.5Nb showed no evidence of abrasion damage and produced the least amount of UHMWPE wear. These results are attributed to the high hardness and excellent wear resistance of zirconia and the excellent wettability of ZrO2 due to its relatively high ionic character in comparison to metals and covalently bonded compounds.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1045-4861
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: To assess new and existing materials for total joint arthroplasty, the authors performed a comprehensive histomorphologic and morphometric analysis of bone to cylinders implanted transversely in the proximal tibia of mature New Zealand white rabbits. Four sterile, cylindrical implants measuring 6.1 × 3.8mm were manually inserted through drill holes in both tibiae with a „line-to-line fit.“ The materials tested included: ASTM F-75 cast cobalt-chrome-molybdenum alloy, commercially pure titanium wrought zirconium-2.5 niobium alloy, zirconium oxide coated zirconium-2.5 niobium alloy, wrought titanium-13 niobium-13 zirconium alloy, and nitrogen diffusion hardened titanium-6 aluminum-4 vanadium alloy. Control animals with or without drill holes were included. The animals were killed by barbiturate overdose 6 months postoperatively. The upper tibiae were harvested and processed for undecalcified histologic sections that were stained with toluidine blue. The sections were examined by an investigator blind to the identity of the implanted materials. A full necropsy was also performed.A collar of lamellar bone, of variable length and thickness, continuous with the original cortex formed a buttress around the implants. There was no evidence of foreign body or inflammatory reaction. The marrow was slightly fatty, but cells of allthree hematopoietic lines were identifiable. The materials investigated had the following ranking in decreasing order of bone contact: Ti-13Nb-13Zr 〉 nitrogen hardened Ti-6Al-4V 〉 C.P. titanium 〉 Zr 2.5Nb 〉ZrO2 coated Zr-2.5Nb 〉 cast Co—Cr alloy. The difference between the groups was statistically significant (p = 0.05). For the variable „average bone layer thickness“ the ranking in decreasing order was: nitrogen hardened Ti-6Al-4V alloy = C.P. titanium 〉 Ti-13Nb-13Zr 〉 ZrO2/Zr-2.5Nb 〉 Zr-2.5Nb 〉 cast Co—Cr alloy (p = 0.19). For the variable „average bone layer thickness in bone contact regions,“ the ranking of the values, in decreasing order were: nitrogen hardened Ti-6Al-4V 〉 C.P. titanium 〉 ZrO2 coated Zr-2.5Nb 〉 Ti-13Nb-13Zr 〉Zr-2.5 Nb 〉 cast Co—Cr alloy (p = 0.02). The final necropsy reports of the animals identified no adverse findings that were concentrated to any particular implant group. The new, lower modulus materials Ti-13Nb-13Zr and Zr-2.5 Nb, and nitrogen hardened Ti-6Al-4V appear to have a similar or superior bone response to Co—Cr alloy when implanted in the rabbit tibia model. © 1993 John Wiley & Sons, Inc.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 22 (1988), S. 281-309 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Previous studies have shown the tendency for frictional heating to occur during articulation of total hip systems in vitro under simulated hip loading conditions. The magnitude of this heating is sufficient to accelerate wear, creep, and oxidation degradation of the UHMWPE bearing surface. It was shown that ceramic articulating systems generate less frictional heating than polished cobalt alloy against UHMWPE. This fricitonal heating is expected to occur primarily for younger, heavier, and more active patients. Thus, long-term performance of the articulating hip system in these patients may not be that predicted from current, body-temperature wear, creep, and degradation studies. Although the tendency to generate frictional heat has been observed only during in vitro simulated hip loading, a heat transfer analysis of this phenomenon is presented to evaluate the ability of the hip joint to dissipate such heating in vivo. Additional experiments were performed using controlled resistance heaters inside a cobalt femoral head to verify the calculated levels of frictional heat and to assess the heat dissipation under simulated in vivo conditions. The effect of blood perfusion on the effective thermal conductivity of the joint capsule is also discussed. The present study describes and analyzes the various heat dissipation mechanisms present both in vitro and in vivo during articulation of metal and ceramic hip systems. From these tests and analyses, it is concluded that frictional heating in the reconstructed hip cannot be effectively removed, and that degredative elevated temperature processes can be expected to occur in vivo to both the UHMWPE and adjacent tissue under extended periods of excessive patient activity. This is particularly true for metal cobalt alloy femoral heads articulating on UHMWPE versus ceramic heads which generate significantly lower levels of heat.
    Zusätzliches Material: 18 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 1005-1017 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: An electron spin resonance (ESR) technique is employed to determine the free radical distribution in the articulating surfaces of retrieved acetabular cups and knee-joint plateaus (retrieved after more than 6 years of implantation). Similar measurements made on samples prepared from cyclically stressed and unstressed cups, and on samples following oxidations in nitric acid and intralipid solutions provided sufficient data to gain more knowledge about the combined chemical and mechanical effects on PE free radicals during implantation. In UHMWPE free radicals are primarily initiated by gamma-ray sterilization; however, during implantation, peroxy (scission type) free radicals are formed and reach a maximum concentration level (equilibrium state) due to oxidation by chemical (hemoglobin and/or synovial fluids) environment of the joints. Subsequently, due to frictional heating and stress in the loading zones, free radical reaction is accelerated and their number is reduced only in those areas. This is consistent with the observations of a temperature rise in acetabular cups during in vitro frictional wear stress tests and in vivo telemetry observations, as reported by others. Compared with the previously reported SEM micrographs the low-free-radical regions are correlated with high-wear areas and the high-free-radical regions with the low-wear areas.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Two novel metal alloys, Ti-13Nb-13Zr and Zr-2.5Nb, have been engineered for applications in orthopedic implants because of their favorable mechanical properties, corrosion resistance, and compatibility with bone and tissue. These alloys also have the ability to form a hard, abrasion-resistant, ceramic surface layer upon oxidative heat treatment (diffusion hardening, DH). Previous studies have indicated that these and other ceramics cause limited hemolysis and exhibit remarkable structural integrity after extended exposure to physiological environments. Such observations suggest that DH Ti-13Nb-13Zr and ZrO2/Zr-2.5Nb could be used successfully as components in blood-contacting devices. Materials intended for such applications must possess properties that do not elicit adverse physiological responses, such as the initiation of the coagulation cascade or thrombus formation. In the present study measurements of prekallikrein activation, fibrinogen adsorption from diluted human plasma, and the strength of fibrinogen attachment as judged by residence-time experiments were performed to evaluate the potential hemocompatibility of these materials. The results of the prekallikrein activation and fibrinogen-retention studies correlated well with two electrochemical properties of the alloys, the open circuit potential and reciprocal polarization resistance. The results indicate that both the original and treated Ti and Zr alloys activate prekallikrein and adsorb as well as retain fibrinogen in amounts similar to other materials used as components of blood-contacting devices. On the basis of these studies, these alloys appear to be promising candidates for cardiovascular applications and merit further investigation. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 20 (1986), S. 1229-1248 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: The process required to sinter porous Co=Cr=Mo alloys results in the formation of substrate porosity through carbide dissolution. Since hot isostatic pressing (HIPing) has been shown to eliminate casting porosity in the Co=Cr=Mo alloy, it is possible that it may be equally effective on pores that are generated from the sintering operation. The effect that HIPing a porous-coated Co=Cr=Mo material has on the fatigue and tensile properties was investigated. Fatigue testing was performed on sintered materials as well as sintered and HIPed materials, both with and without a porous coating. Further, the effect of varying coating thickness on the resulting fatigue strength of sintered and HIPed materials was studied. Light microscopy was performed in order to define the microstructural changes brought about by the various thermal cycles. Scanning electron microscopy was utilized to define the crack initiation process. The fatigue strength of uncoated “as sintered” materials was found to be reduced by 34% relative to the “as cast” condition. The same material that was HIPed revealed a fatigue strength slightly lower than the “as cast” condition. It was found that porous coatings created preferential sites for fatigue crack initiation. However, the presence of the coating did not further reduce the fatigue strength of “as sintered” materials because of the already low strength created by the sintering operation. Materials that were sintered exhibited a lowering in both tensile strength and elongation to failure relative to the “as cast” condition. The HIPing of sintered materials improved both fatigue and tensile properties relative to the “as sintered” condition.
    Zusätzliches Material: 15 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Publikationsdatum: 1996-10-01
    Print ISSN: 0007-4861
    Digitale ISSN: 1432-0800
    Thema: Energietechnik , Medizin
    Publiziert von Springer
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...