ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 41 (1998), S. 371-376 
    ISSN: 0021-9304
    Keywords: titanium alloy ; particulate debris ; total joint arthroplasty ; monocytes/macrophages ; cytokines ; SDS-PAGE ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study tested whether macrophages respond differently to retrieved titanium-alloy particles than they do to machined titanium-alloy particles and assessed whether pretreatment of machined titanium-alloy particles with human serum would influence macrophage activation and cytokine release in vitro. Human monocyte/macrophages were isolated from normal healthy donors and exposed to increasing concentrations of machined and retrieved titanium-alloy particles. The profile of cytokine release was determined by commercially available ELISA kits. Machined titanium-alloy particles were opsonized with human serum and added to macrophage cultures. Serum protein binding was confirmed by SDS-PAGE analysis. The results showed that machined titanium-alloy particles and retrieved titanium-alloy particles stimulate a similar level of cytokine release when tested at comparable concentrations. Opsonization of the machined particles with human serum increased the macrophage release of cytokines in the first 12 h after exposure compared to nonopsonized particles. At 24 h, the opsonized particles stimulated significantly higher levels of cytokine release, but only at the greatest particle concentrations. This study demonstrates that machined titanium alloy induces a metabolic response in macrophages similar to that of titanium-alloy particles retrieved from failed total hip arthroplasty. In addition, these data show that serum protein binding to orthopedic biomaterial debris alters the macrophage reaction to the particles. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 371-376, 1998.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...