ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • protein luminescence  (1)
  • steady-state anisotropy  (1)
  • 1
    ISSN: 1573-4994
    Keywords: λcI reprossor ; phosphorescence ; triplet lifetimes ; protein luminescence ; 5-hydroxy-l-tryptophan
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have measured the steady-state phosphorescence and decay times of wild-type λcI repressor and compared it with that of a modified λcI repressor in which 〉 95% of the tryptophans were replaced with 5-hydroxy-l-tryptophan (5-OHTrp). The wild-type and 5-OHTrp-λcI repressors are spectroscopically distinct such that we can selectively excite the 5-OHTrp-λcI even in the presence of a 15-fold molar excess ofN-acetyltryptophanamide (NATrpA). The phosphorescence band of wild-type λcI is red-shifted by 3 nm relative to NATrpA, characteristic of buried tryptophan. Similarly, the phosphorescence of 5-OHTrp-λcI repressor is red-shifted relative to the model, 5-OHTrp, showing that according to the phosphorescence, the modified repressor is structurally indistinguishable from the native repressor. While the phosphorescence decay of both NATrpA and 5-OHTrp are single exponentials, the decay of both wild-type and 5-OHTrp-λcI repressors is complex, requiring three decay components whose fractional contributions to the phosphorescence are the same for both repressors. Because the 5-OHTrp phosphorescence can be excited at wavelengths outside the absorbance range of tryptophan and DNA, a protein spectrally enhanced with this emitter will aid the investigations of protein-protein or protein-DNA interactions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4994
    Keywords: Fluorescence anisotropy decay ; steady-state anisotropy ; constrained optimization ; Lagrange multiplier method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Time-resolved fluorescence anisotropy is an invaluable method for investigating the internal and rotational dynamics of biomolecules. The range of rotational motions detectable by anisotropy decay is limited by the fluorescence lifetime; typically, a depolarizing motion may be resolved if the associated correlation time is between 0.1 and 10 times the intensity decay lifetime. To extend that range and to improve the recovery of anisotropy decay parameters, a general analytical method has been developed. This procedure utilizes a modification of Lagrange multiplier methods to constrain the values of the iterated kinetic parameters during nonlinear least-squares analysis of anisotropy decay data. The form of the constraint equation is derived from the classic relationship between the decay parameters and the steady-state anisotropy, which can be simply and accurately measured. Application of the constraint to analyses of synthetic data sets increased the accuracy of recovery by decreasing the uncertainty in the iterated parameters. The constraint also enabled the accurate recovery of correlation times that were a factor of 30 greater than the fluorescence lifetime, although it did not improve recovery of correlation times that were much shorter than the lifetime. Using this technique, it should now be possible to characterize the dynamics of larger macromolecules and assemblies than those that can currently be studied by fluorescence anisotropy decay.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...