ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • passive sampler  (1)
Collection
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Environmental monitoring and assessment 62 (2000), S. 39-54 
    ISSN: 1573-2959
    Keywords: air monitoring ; chemical model ; nitrogen oxides ; passive sampler
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Measurement of nitrogen dioxide using passivediffusion tube over 22 months in Cambridge, U.K. areanalysed as a function of sampler exposure time, andcompared with NO2 concentrations obtained from aco-located chemiluminescence analyser. The averageratios of passive sampler to analyser NO2 at acity centre site (mean NO2 concentration 22 ppb)are 1.27 (n = 22), 1.16 (n = 34) and 1.11 (n = 7) forexposures of 1, 2 and 4-weeks, respectively. Modellingthe generation of extra NO2 arising from chemicalreaction between co-diffusing NO and O3 in thetube gave a ratio (modelled/measured) of 1.31 for1-week exposures. Such overestimation is greatest whenNO2 constitutes, on average, about half of totalNOx (= NO + NO2) at the monitoring locality.Although 4-week exposures gave concentrations whichwere not significantly different from analyserNO2, there was no correlation between thedatasets. At both the city-centre site and anothersemi-rural site (mean NO2 concentration 11 ppb)the average of the aggregate of four consecutive1-week sampler exposures or of two consecutive 2-weeksampler exposures was systematically greater than fora single 4-week exposure.The results indicate two independent and opposingsystematic biases in measurement of NO2 bypassive diffusion sampler: an exposure-timeindependent chemical overestimation with magnitudedetermined by local relative concentrations of NO andO3 to NO2, and an exposure-time dependentreduction in sampling efficiency. The impact of theseand other potential sources of systematic bias on theapplication of passive diffusion tubes for assessingambient concentrations of NO2 in short (1-week)or long (4-week) exposures are discussed in detail.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...