ISSN:
1573-4862
Keywords:
Ultrasonic
;
stress measurements
;
interfacial stress
;
NiTi
;
NDE
Source:
Springer Online Journal Archives 1860-2000
Topics:
Electrical Engineering, Measurement and Control Technology
,
Mathematics
Notes:
Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF00711095