ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 8 (1993), S. 21-24 
    ISSN: 0884-3996
    Keywords: Chemiluminescence ; haemodialysis ; oxalate determination ; urolithiasis ; peroxyoxalate chemiluminescence ; ascorbic acid ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: We describe a new sensitive and specific method for determination of oxalate in human serum. By using the chemiluminescence decay of monoperoxyoxalic acid very low concentrations of oxalate (200 nmol/L) can be determined. The mean serum oxalate level in apparently healthy controls was 14.5 ± 8.5 m̈mol/L. Supplementation of ascorbic acid leads to an increase in serum oxalate level. While serum oxalate concentrations of calcium oxalate stone formers (x = 16.4 ± 9.8 m̈mol/L) are not significantly different from the control group, an extreme increase of serum oxalate is evident in haemodialysis patients. The serum oxalate concentration decreased during dialysis treatment from 141.4 ± 32.1 m̈mol/L to 36.4 ± 12.7 m̈mol/L.
    Additional Material: 3 Ill.