ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • graft polymerization  (2)
  • reprocessing  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 53 (1998), S. 19-26 
    ISSN: 1572-8943
    Keywords: differential scanning calorimetry ; glass fibre reinforced ; oxidative stability ; polyamide 66 ; reprocessing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The thermal stability of heat-stabilised polyamide 66 in an oxidative environment is evaluated by DSC. The oxidative stability of the polyamide decreases as a result of repeated injection moulding. The results also indicate that the presence of glass fibres in the polyamide has a negative influence on the oxidative stability. Both isothermal and dynamic DSC measurements seem to be useful tools for assessing the stability of polyamides and there is a relationship between data determined using both procedures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 33 (1995), S. 2039-2047 
    ISSN: 0887-624X
    Keywords: graft polymerization ; grafting rate ; grafting kinetics ; EB-irradiation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Linear low density polyethylene (LLDPE) film was irradiated by electron beam in air or argon prior to grafting in aqueous solutions of acrylamide containing 0.05% of Mohr's salt. The grafting kinetics was studied with pre-irradiation doses in the range of 2.5-25 Mrad and in the temperature range of 40-70°C. Grafting rates and final degrees of grafting were higher for LLDPE pre-irradiated in air than for LLDPE pre-irradiated in argon. The overall activation energies for the grafting reaction were dose-dependent. Above 5 Mrad, the overall activation energies were higher for LLDPE pre-irradiated in argon which is interpreted as being due to crosslinking of the LLDPE. © 1995 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 33 (1995), S. 2049-2055 
    ISSN: 0887-624X
    Keywords: graft polymerization ; grafting rate ; electron beam irradiation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: LLDPE film pre-irradiated by electron beam (EB) in air and argon was grafted in an aqueous acrylamide solution containing Mohr's salt in the concentration range 0.0025-2% The grafting rate and yield were strongly dependent on the Mohr's salt concentration, mainly as a result of chain termination. The exponential grafting rate dependence on the pre-irradiation dose was quite insensitive to a hundred-fold variation in Mohr's salt concentration. © 1995 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...