ISSN:
0899-0042
Keywords:
enantioselective
;
chromatography
;
validation
;
column-switching
;
robotic
;
pharmacokinetic
;
Chemistry
;
Organic Chemistry
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
Notes:
Lifibrol, a new drug for the treatment of hypercholesterolemia, contains a stereogenic center bearing a secondary alcohol group. A normal-phase achiral-chiral HPLC separation of the enantiomers of lifibrol and two of its metabolites was developed and validated for quantitation in dog plasma. A silica and a Chiralcel OD-H column were operated in series and all six enantiomeric components and internal standard were directly separated. An initial solid-phase extraction (phenyl) clean-up step and a column-switching step to eliminate late-eluting compounds were also utilized. The solid-phase extraction step was automated using a robotic system. Assay development, validation, and application of the method to a bioavailability study of the racemate and enantiomers of lifibrol in dogs are described. The lower limit of quantitation was 0.0125 μg/ml for each enantiomer of lifibrol using 200 μl of dog plasma with UV detection (255 nm). In dog plasma following oral or intravenous administration of the racemate, the (R)/(S) ratio of the enantiomers of lifibrol was greater than one and increased with time. Following administration of the individual enantiomers, chiral inversion of the (S)-enantiomer but not the (R)-enantiomer was observed. © 1994 Wiley-Liss, Inc.
Additional Material:
9 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/chir.530060211
Permalink