ISSN:
0197-8462
Schlagwort(e):
Macaca monkeys
;
electrocardiogram
;
blood pressure
;
stationary magnetic fields
;
Life and Medical Sciences
;
Occupational Health and Environmental Toxicology
Quelle:
Wiley InterScience Backfile Collection 1832-2000
Thema:
Biologie
,
Physik
Notizen:
Simultaneous measurements were made of the electrocardiogram (ECG) and the intraarterial blood pressure of adult male Macaca monkeys during acute exposures to homogeneous stationary magnetic fields ranging in strength up to 1.5 tesla. An instantaneous, field strength-dependent increase in the ECG signal amplitude at the locus of the T wave was observed in fields greater than 0.1 tesla. The temporal sequence of this signal in the ECG record and its reversibility following termination of the magnetic field exposure are consistent with an earlier suggestion that it arises from a magnetically induced aortic blood flow potential superimposed on the native T-wave signal. No measurable alterations in blood pressure resulted from exposure to fields up to 1.5 tesla. This experimental finding is in agreement with theoretical calculations of the magnetohydrodynamic effect on blood flow in the major arteries of the cardiovascular system.
Zusätzliches Material:
1 Ill.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1002/bem.2250040102
Permalink