ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Roman aqueduct  (1)
  • laser ablation  (1)
Collection
Keywords
Language
Years
  • 1
    Publication Date: 2021-07-21
    Description: The fourth‐ and fifth‐century aqueduct system of Constantinople is, at 426 km, the longest water supply line of the ancient world. Carbonate deposits in the aqueduct system provide an archive of both archaeological developments and palaeo‐environmental conditions during the depositional period. The 246‐km‐long aqueduct line from the fourth century used springs from a small aquifer, whereas a 180‐km‐long fifth‐century extension to the west tapped a larger aquifer. Although historical records testify at least 700 years of aqueduct activity, carbonate deposits in the aqueduct system display less than 27 years of operation. This implies that the entire system must have been cleaned of carbonate, presumably during regular campaigns. A 50‐km‐long double‐aqueduct section in the central part of the system may have been a costly but practical solution to allow repairs and cleaning of the aqueducts of carbonate to ascertain a continuous water supply to the city. The fifth‐century channel was commonly contaminated with clay, caused by the nature of the aqueduct system and possible local damage to the channel. This clay‐rich water could have been one of the reasons for the construction of large reservoirs in Constantinople. image
    Description: Leverhulme Trust http://dx.doi.org/10.13039/501100000275
    Description: Deutsche Forschungsgemeinschaft http://dx.doi.org/10.13039/501100001659
    Keywords: 552.5 ; Byzantine ; carbonate ; Constantinople ; Roman aqueduct ; water supply
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2021-07-23
    Description: The in situ measurement of Sr isotopes in carbonates by MC-ICP-MS is limited by the availability of suitable microanalytical reference materials (RMs), which match the samples of interest. Whereas several well-characterised carbonate reference materials for Sr mass fractions 〉 1000 µg g−1 are available, there is a lack of well-characterised carbonate microanalytical RMs with lower Sr mass fractions. Here, we present a new synthetic carbonate nanopowder RM with a Sr mass fraction of ca. 500 µg g−1 suitable for microanalytical Sr isotope research (‘NanoSr’). NanoSr was analysed by both solution-based and in situ techniques. Element mass fractions were determined using EPMA (Ca mass fraction), as well as laser ablation and solution ICP-MS in different laboratories. The 87Sr/86Sr ratio was determined by well-established bulk methods for Sr isotope measurements and is 0.70756 ± 0.00003 (2s). The Sr isotope microhomogeneity of the material was determined by LA-MC-ICP-MS, which resulted in 87Sr/86Sr ratios of 0.70753 ± 0.00007 (2s) and 0.70757 ± 0.00006 (2s), respectively, in agreement with the solution data within uncertainties. Thus, this new reference material is well suited to monitor and correct microanalytical Sr isotope measurements of low-Sr, low-REE carbonate samples. NanoSr is available from the corresponding author.
    Keywords: 551.9 ; strontium isotopes ; laser ablation ; reference material ; calcium carbonate ; nanopowder ; MC-ICP-MS
    Language: English
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...