ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Four different acetabular replacement designs and 2 femoral head replacement designs made out of high density alumina ceramic have been tested in sheep with postoperative survival times of up to 11 months (Frialit 99: Al2O3 99.6%, MgO 0.4%).It can be concluded from these experiments that a cement free implantation technique with alumina requires a primary rigid fixation of the implant to bone, with the possibility for new bone growth along the ceramic and into grooves and macroscopic holes for further interdigitation. Three different solutions for the acetabular component can be recommended for human application.In addition, an all ceramic femoral prosthesis has been tested for bending strength in its neck region. Twenty prostheses have been fractured, all of which showed values for bending strength far higher than the physiological neck fracture level (900 kp/cm2). The present state of development of all ceramic prostheses is discussed. Up to now, the development of fibrous tissue between the bone and the ceramic implant has caused reservations with human implantation. The direct definite anchorage problem has to be resolved first.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 188 (1987), S. 651-663 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The transition from the nematic melt to the solid state in a rigid rod-like copolymer was found to be characterized by unusual thermodynamic and kinetic properties. The transition occurred with negligible volume changes. The enthalpy and the entropy of the transition were found to be lower by at least one order of magnitude in comparison to the values usually observed for a crystal to nematic transition. The ordered solid state displays a glass transition and its structure is characterized by high symmetry, i.e., an orthorhombic one. Dielectric relaxation studies, investigations on the plastic flow properties of the solid state and studies on the dynamical mechanical properties revealed a high degree of rotational freedom already at room temperature in the solid state. These experimental findings led us to the conclusion that the solid state displays a three-dimensional positional long range order but is rotationally disordered with respect to rotations about the long axes of the rod-like molecules. The structure is similar to those of plastic crystals known for spherical molecules such as cyclopentane, or to smectic E modifications known for rod-like molecules. Also the properties reported above for the rod-like copolymers resemble those reported in the literature for plastic crystals.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 32 (1994), S. 1399-1414 
    ISSN: 0887-624X
    Keywords: plasma polymers ; oxidation ; XPS ; FTIR ; SEM ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Long-term compositional changes were observed when n-hexane plasma polymers were stored in air at ambient temperature. These post-deposition changes were monitored over periods exceeding one year using XPS, grazing angle FTIR, and SEM. A rapid initial increase in the oxygen content was followed by a slower oxygen uptake, which continued for many months. In contrast to the reported autocatalytic acceleration of the oxidation of polyolefins, the rate of oxidation of n-hexane plasma polymers was found to decrease continuously, and it did not proceed to the same extent toward higher oxidation states. The plasma polymer coatings did not show physical manifestations of oxidative degradation such as cracking, reduction in thickness, or loss of physical integrity. Comparison of the XPS and FTIR data suggested that the top few nanometers of the plasma polymer coatings oxidized at a faster rate than the “bulk.” The experimental data were interpreted using a model comprising reactions known from the oxidative degradation of polyolefins: carbon-centered radicals, trapped in the course of the plasma deposition, combine with atmospheric oxygen to form metastable peroxy radicals and hydroperoxides, which decompose to generate a variety of stable product groups such as hydroxyl, carbonyl, and carboxylic groups. There was broad agreement between the XPS data and the time dependence of particular species in model calculations. © 1994 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 36 (1998), S. 985-1000 
    ISSN: 0887-624X
    Keywords: plasma polymers ; methyl methacrylate ; oxidation ; long-term stability ; XPS ; FTIR ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Plasma polymer films were deposited from methyl methacrylate (MMA) vapor under various plasma conditions and XPS and FTIR used to study the changes to the compositions of the films as they were stored in air for longer than 1 year. The plasma power input per monomer mass unit (W/FM) markedly affected the composition of the freshly deposited MMA plasma polymers. A low value of W/FM led to a high degree of retention of the original monomer structure, whereas a high value of W/FM resulted in substantial monomer fragmentation and the formation of a partially unsaturated material considerably different to conventional PMMA. As the MMA plasma coatings were stored in ambient air after fabrication, all showed spontaneous oxidative changes to their composition, but the extents and reaction products differed substantially. Deposition at low W/FM led to moderate oxidative changes, whereas high power led to a pronounced increase in the oxygen content over time and resulted in a wide range of carbon-oxygen functionalities in the aged material. As the initial compositions/plasma deposition conditions thus influenced the oxidative postdeposition reactions, MMA plasma polymers deposited under different conditions not only varied in their initial composition but then became even more diverse as they aged. © 1998 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 36: 985-1000, 1998
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 36 (1998), S. 633-643 
    ISSN: 0887-624X
    Keywords: plasma polymerization ; polyaniline ; free radicals ; surface characterization ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The radio-frequency plasma polymerization technique was used to polymerize aniline onto polymer substrates including perfluorinated ethylene propylene copolymer. The plasma-polyaniline films were characterized by ultraviolet/visible absorption spectroscopy, Fourier transform infrared spectroscopy, electron spin resonance, X-ray photoelectron spectroscopy, scanning electron microscopy, and contact angle measurements. Preliminary conductivity measurements were also carried out. It was demonstrated that the chemical and physical characteristics of the plasma-polymerized poly-aniline films changed significantly with discharge conditions, indicating the possibility for tailoring the structure and properties of the polyaniline films by optimizing the discharge conditions. In particular, the contents of quinoid sequences and aliphatic crosslinking moieties were found to increase with increasing power input and/or discharge duration. By contrast, the number of free radicals trapped in the polyaniline films and their mobility were shown to increase with decreasing the power input and/or discharge duration within the plasma conditions covered in this study. Furthermore, a correlation was found between surface hydrophilicity of the resultant plasma-polyaniline films and the atomic ratio of C to N. © 1998 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 36: 633-643, 1998
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Advanced Materials 4 (1992), S. 690-691 
    ISSN: 0935-9648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-9648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Advanced Materials 2 (1990), S. 497-498 
    ISSN: 0935-9648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1040-0397
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preconcentration voltammetric behavior of technetium at a carbon paste electrode modified with thenoyltrifluoroacetone (TTA) has been investigated. It is demonstrated that enrichment of technetium on the electrode surface by complex formation with TTA is possible. Deposition of Tc(IV) takes place due to a purely chemical reaction resulting probably Tc(TTA)4. Enhanced accumulation occurs if a reductive electrode potential of -0.4 V is applied, which presumably causes fixation in the form of Tc(TTA)3. In the subsequent voltammetric scan a characteristic peak at about -40 and +40 mV, respectively, is obtained. Tc(VII) is not deposited, unless a reduction potential of at least -0.6 V is applied, with the pH of the solution optimally chosen at 3.5. Therefore, it is possible to discriminate between Tc(IV) and Tc(VII).
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1022-1336
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Adsorption and aggregation of carbosiloxane dendrimers on mica and pyrolytic graphite were investigated by scanning force microscopy (SFM). The aggregation process started from (i) single molecules which coagulated to (ii) clusters and (iii) fluid droplets followed by formation of (iv) a complete layer on the solid substrate. The molecules were displayed as a globular particle with a diameter of about 2.5 nm. Tapping SFM of the liquid was possible due to the fact that the dendrimer undergoes a transition to a viscoelastic state below the tapping frequency of about 360 kHz. Dynamic shear compliance experiments have shown a plateau of 5 · 10-7 Pa-1 around this frequency. Dendrimer droplets slowly spread into polygonal lamellae with a thickness of two molecular layers. The structures indicate a rather regular dense packing of the globular molecules.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...