ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of bioenergetics and biomembranes 29 (1997), S. 3-10 
    ISSN: 1573-6881
    Keywords: Mitochondria ; MCC ; PSC ; import pathway ; membrane channels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Physics
    Notes: Abstract Mitochondrial biogenesis requires the import of hundreds of different proteins from the cytosol. Protein import into mitochondria is a multistep pathway that includes recognition of precursor proteins by machinery both in the cytoplasm and on the mitochondrial surface, translocation of the precursor across one or both mitochondrial membranes, and folding of the protein after its import into the organelle. Over the past several years, many components of the import machinery have been identified using both biochemical and genetic methods. Recently, significant progress has been made determining the function of some of these import proteins. One purpose of this minireview is to summarize our current understanding of the import pathway, and to introduce the topics of the minireviews that will follow. The other goal of this minireview is to discuss recent findings suggesting that proteins are translocated across both the mitochondrial inner and outer membranes through aqueous channels.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The formulas used for calculation of diffusion coefficients in free diffusion are stated. The calculations request the 0th, first, and second moments of the curve to be calculated. This is usually made by calculation of moments of segments of the figure between the curve and the base line, followed by summation.It is proposed to replace this rather laborious procedure by the use of an integrator. A survey is given on the theoretical background and the principles for such instruments. Some equations are stated for the type of instrument used in these investigations. From these equations it is possible, by inserting the values in the formulas used for the calculation of diffusion coefficients, to express the latter for a certain curve as a function of the rotation of the three integration rolls in the instrument. The relative influence on the final result for these integration rolls is considered. For one of the rolls this can be shown to be insignificant, when the moment axis is chosen very near the central axis of the curve. Our experience has shown the standard error in a normal measurement to be 2 × 10-3 and 3 × 10-3 of a revolution for the two other integration rolls. Some curves are given which show the requests one must put on the relative number of rotations for these rolls to make certain that the relative standard error, introduced by the integrator, will not exceed certain values on the final result. The curves are drawn for values from 2 to 0.1%.From a known Gaussian distribution a set of diffusion curves is drawn. The diffusion coefficient is calculated from these curves both by the usual method and by the integrator. The results obtained by the integrator compare well with those by the usual method if the peaks are not drawn too narrow.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-28
    Description: The results of a study are presented for terminology definition, identification of functional requirements, technolgy assessment, and proposed end effector development strategies for the Space Station Program. The study is composed of a survey of available or under-developed end effector technology, identification of requirements from baselined Space Station documents, a comparative assessment of the match between technology and requirements, and recommended strategies for end effector development for the Space Station Program.
    Keywords: SPACECRAFT INSTRUMENTATION
    Type: NASA-TM-100488 , NAS 1.15:100488
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...