ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1741-0444
    Keywords: Oscillometric method ; Pressure-volume relationship ; Transmural pressure ; Vascular unloaded state ; Volume pulsation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract To analyse the mechanism of the occurrence of the maximum volume pulsation in an artery during the application of counterpressure, the static, and dynamic pressure-volume (P-V) relationship was measured in excised arterial segments placed in a compression chamber. Teh volume change caused by perfusing the segment with a sinusoidal pump was detected by an infrared photoelectric plethysmograph during the application of counterpressure. It was revealed that the characteristic change in the amplitude of volume pulsation in response to the gradual change in the counterpressure was due to the nonlinearity of the P-V relation of the artery, and that the value of the counterpressure showing the maximum pulsation amplitude was coincided with the mean arterial pressure. From this evidence it was concluded that the maximum volume pulsation occurs when the transmural pressure was equal to zero, i.e. the arterial wall isunloaded. Based on the results a new oscillometric method for the indirect measurement of systolic and mean arterial pressure in an arterial segment was designed. Through the comparison of data with the actual pressure produced by perfusing the segment, it was demonstrated that systolic and mean arterial pressure can be indirectly measured by this technique within ±3 mm Hg error.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1741-0444
    Keywords: Finger arterial pressure ; Indirect systolic and mean pressure ; Oscillometric method ; Photoelectric plethysmography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract With a new oscillometric method equipped with a transmittance infrared photoelectric plethysmograph, indirect systolic, and mean arterial pressures were measured in 12 normotensive and hypertensive subjects with systolic and mean arterial pressures ranging from 55 to 163 mmHg and from 95 to 200 mmHg, respectively. The pressure values obtained by this method were compared with direct measurements of the brachial intra-arterial pressure recorded simultaneously. A fairly good correlation between the pairs of simultaneous data from these two methods were obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...