ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Occupational Health and Environmental Toxicology  (2)
Collection
Keywords
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 18 (1997), S. 531-540 
    ISSN: 0197-8462
    Keywords: carcinogenicity ; rat ; magnetic field ; elf ; two-year bioassay ; lifetime exposures ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Male and female F344 rats, 48 per exposure group, were sham exposed (Group A) or exposed to 0.5 (Group B) and 5 mT (Group C) magnetic fields for two years. Animals were exposed from 5-109 weeks of age in SPF conditions according to the OECD test guideline No. 451. Average exposure was 22.6 hr/day. No significant differences in body weight and food consumption were observed between the sham and exposed groups. At the end of the exposure period, survival rates of the male rats were 73, 83, and 79%, and those of the females, 77, 79, and 75% for Groups A, B, and C, respectively, with no significant differences between groups. Differential counts of leukocytes were measured at the 52nd, 78th, and 104th weeks of exposure and no significant differences were observed between the exposure groups. All survivors were euthanized on schedule, and all the organs and tissues suspected of tumoral lesions were examined histopathologically. Incidences of mononuclear cell leukemia in the male and the female rats were 5, 4, 4 and 8, 6, 7 for Groups A, B and C, respectively; incidences of malignant lymphoma in the female rats were 0, 1 and 1. Neither significant increases nor acceleration of incidence of leukemia were observed. Incidences of brain and intracranial tumors did not increase in the exposed groups. Incidences of both benign and malignant neoplasms showed no significant difference between the exposed and sham exposed groups with one exception: fibroma of the subcutis in the male rats, which was considered not to be a statistically significant when evaluated with respect to the historical control data in our laboratory. Bioelectromagnetics 18:531-540, 1997. © Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 14 (1993), S. 535-544 
    ISSN: 0197-8462
    Keywords: exposure facility ; chronic exposure of rats ; magnetic field ; ELF ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The facility consists of a 12 × 11.5 × 2.4 m high room containing six sets of exposure apparatus and the other equipment necessary to maintain a pathogen-free system. The apparatus sets produced 5 mT (rms), 0.5 mT, or a sham exposure. The apparatus was arranged in the room to minimize the fringing field of the 5 mT set at the sham position. Each set was 3.85 × 1.80 × 0.66 m in outside dimension, containing 24 cages in the magnetically homogeneous region. The apparatus was designed using Harvey's figure-eight-configuration and generated a horizontal sinusoidal alternating field. In order to save electric power, the coil of the apparatus constituted a 50 Hz LC resonance circuit with a condensor bank to which electric power was supplied to compensate losses. Magnetic flux density was kept constant by controlling the coil current. Although mild steel was used in the skeleton of the building, the fringing flux at the sham was as low as 0.1 to 1 μT. Stainless steel was used for ventilating ducts, racks for the cages, cage covers, feeder baskets, and watering nozzles. The homogeneity of the field was measured to be ± 10% in the animal residence area, and food and water consumption was found to be unaffected by the field. At 5 mT, the coil current was 370 A, and the hollow coil was cooled by a stream of 20°C water to prevent both heat and dew on the coil surface. Vibration and acoustic noise was prevented by fiber reinforced plastic framework of the coil. High harmonic distortion was not observed at the output terminal of the coil driver. The facility has operated without trouble for 2 years. © 1993 Wiley-Liss, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource