ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • OPTICS  (3)
  • Product surveillance, postmarketing  (3)
  • 1
    ISSN: 1573-739X
    Keywords: Adverse effects ; Astemizole ; Drug interactions ; Overdose ; Probability ; Product surveillance, postmarketing ; Terfenadine ; Torsades de pointes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Recently, the use of astemizole and terfenadine, both non-sedating H1-antihistamines, caused considerable concern. Several case reports suggested an association of both drugs with an increased risk of torsades de pointes, a special form of ventricular tachycardia. The increased risk of both H1-antihistamines was associated with exposure to supratherapeutic doses; for terfenadine the risk was also associated with concomitant exposure to the cytochrome P-450 inhibitors ketoconazole, erythromycin and cimetidine. To predict the size of the population that runs the risk of developing this potentially fatal adverse reaction in the Netherlands, the prevalence of prescribing supratherapeutic doses and the concomitant exposure to terfenadine and cytochrome P-450 inhibitors was studied. Data were obtained from the PHARMO data base in 1990, a pharmacy-based record linkage system encompassing a catchment population of 300,000 individuals. The results of the study showed that the prescribing of supratherapeutic doses and the concomitant exposure to terfenadine and cytochrome P-450 inhibitors was low. Furthermore, the results of a sensitivity analysis showed that the risk of fatal torsades de pointes has to be as high as 1 in 10,000 to cause one death in the Netherlands in one year.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pharmacy world & science 17 (1995), S. 133-137 
    ISSN: 1573-739X
    Keywords: Adverse effects ; Bromocriptine ; Cardiovascular diseases ; Cerebrovascular disorders ; Incidence ; Lactation ; Product surveillance, postmarketing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The use of bromocriptine for the suppression of postpartum lactation drew widespread attention to a potentially increased risk for cardiovascular and cerebrovascular adverse effects. To estimate the incidence of these events a follow-up study was performed among 2,130 women of 15–44 years of age who were treated with a course of bromocriptine in 1990–1992. None of these women were admitted to the hospital for cardiovascular or cerebrovascular events. However, the incidence of pregnancy hypertension and the use of cardiovascular drugs increased considerably in the last 2 months before delivery. Therefore, cardiovascular or cerebrovascular events can probably be explained by pre-existing morbidity rather than by the use of bromocriptine. We estimated, using a ‘worst-case’ analysis, that fewer than 2 Dutch women each year would develop serious cardiovascular or cerebrovascular events.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-739X
    Keywords: Acitretin ; Data collection ; Dermatologists ; Drug utilization ; Epidemiological methods ; Pharmacists ; Product surveillance, postmarketing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract In October 1990, a recall procedure was issued regarding the drug acitretin. The recommended post-therapy contraception period after acitretin therapy was extended from 2 months to 2 years. For a postmarketing surveillance study, we recruited a cohort from the source population of women aged 15–45 years who were exposed to acitretin. Recruitment occurred through dermatologists, and pharmacists plus dispensing general practitioners. We describe the speed of and the response to the recruitment procedures, and the representativeness of the recruited cohort. We also studied whether the individuals who gave informed consent would have preferred to be recruited by either dermatologists or pharmacists, and whether the information obtained from pharmacists and dispensing general practitioners was valid. This study revealed that pharmacists and dispensing general practitioners (drug dispensers) recruited their subjects rapidly, with no or little selection; they attained a 42% response. Dermatologists recruited their subjects slowly and selectively; they attained a 24% response. The majority of women (60%) recruited by dermatologists would have given their informed consent if they would have been recruited by their pharmacists. Drug dispensers are essential contributors to the recruitment of a study population. We do advise that such recruitment for a postmarketing surveillance study occurs by means of a collaboration between pharmacists and physicians.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-19
    Description: Effects of diffraction on the performance of electronic heterodyne readout of moire fringes are investigated. The sensitivity, accuracy, and resolution of the system are calculated, and it is shown that these features are significantly improved compared with the conventional intensity moire readout technique. The sensitivity of the system can be tripled without changing the distance between gratings. The system was evaluated experimentally by measuring the refractive-index derivatives of a weak phase object consisting of a large KD(asterisk)P crystal. Effects of nonlinear fringe modulation were studied both theoretically and experimentally. It is shown that in this case the electronic phase is not linearly related to the fringe shift, and calibration of the system is necessary.
    Keywords: OPTICS
    Type: Applied Optics (ISSN 0003-6935); 25; 895-902
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-28
    Description: Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.
    Keywords: OPTICS
    Type: NASA-CR-182982 , NAS 1.26:182982
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-12
    Description: The effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are theoretically and experimentally investigated. The intensity transmission distribution of the transparency, the moire image, the heterodyne readout, and the spatial and angular resolution are analytically discussed. The deferred electronic heterodyne technique is evaluated by measuring small fringe shifts caused by a weak phase object. It is found that this technique can be applied for accurate and sensitive readout of moire fringes of unsteady phase objects. The theoretical study shows that the accuracy and sensitivity of the system are weakly affected by diffraction and nonlinear photographic emulsion characteristics. Nonlinear recording does not affect the spatial resolution of the system.
    Keywords: OPTICS
    Type: Optical Society of America, Journal, A: Optics and Image Science (ISSN 0740-3232); 4; 1798-180
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...