    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 1 (1987), S. 79-90 
    ISSN: 0886-9383
    Keywords: Numerical deconvolution ; Peak resolution ; Peak separation ; Iterative deconvolution ; Jansson's method ; Super-resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Severely overlapped gas chromatographic peaks can be resolved using Jansson's method. Jansson's method is an iterative nonlinear deconvolution technique and consists of Van Cittert's algorithm with the relaxation factor a function of the kth estimate of the peak shape. The maximum peak amplitude of the instrument and peak non-negativity serve as constraints to improve the peak estimate. Super-resolution is achieved without significantly degrading the chromatogram signal-to-noise ratio. The method only requires a knowledge of the instrument impulse response function and maximum peak height.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 1 (1987), S. 175-183 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Jansson's method ; Peak resolution ; Numerical deconvolution ; Super resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In a previous paper,1 Jansson's method was used to deconvolve overlapped gas chromatographic peaks. It was found that this method gave improved performance over conventional techniques such as perpendicular drop and shoulder quantitation.2,3 This paper will present the results of a comprehensive test of Jansson's method using several sample mixtures. These results will be compared to what can be obtained by using shoulder quantitation, perpendicular drop or an instrument with a longer column. A relatively large number of tests will be performed for each of the four mentioned methods of peak resolution, so there will be a reasonable statistical basis for the goodness of Jansson's method to resolve fused gas chromatographic peaks for a given set of instrument conditions. A brief review of Jansson's method and the modeling of a gas chromatographic process will also be presented.