Publication Date:
2019-07-13
Description:
After 6.8 years on orbit, degradation has been observed in the mechanical properties of second-surface metalized Teflon(Reg) FEP (fluorinated ethylene propylene) used on the Hubble Space Telescope (HST) on the outer surface of the multi-layer insulation (MLI) blankets and on radiator surfaces. Cracking of FEP surfaces on HST was first observed upon close examination of samples with high solar exposure retrieved during the first servicing mission (SM1) conducted 3.6 years after HST was put into orbit. Astronaut observations and photographs from the second servicing mission (SM2), conducted after 6.8 years on orbit, revealed severe cracks in the FEP surfaces of the MLI on many locations around the telescope. This paper describes results of mechanical properties testing of FEP surfaces exposed for 3.6 years and 6.8 years to the space environment on HST. These tests include tensile testing, surface micro-hardness testing, and bend testing.
Keywords:
Nonmetallic Materials
Type:
NASA/TM-1998-206618
,
E-11051
,
NAS 1.15:206618
,
AIAA Paper 98-0895
,
Aerospace Sciences Meeting and Exhibit; Jan 12, 1998 - Jan 15, 1998; Reno, NV; United States
Format:
application/pdf
Permalink