Publication Date:
2019-06-27
Description:
Nondestructive direct measurement of residual surface stresses in metals can be made because metal under stress has a different electrochemical solution potential than in the unstressed condition. The method uses two matched electrolytic cells to cancel extraneous effects on the actual solution potential of the metal specimen.
Keywords:
MATERIALS
Type:
KSC-10237
Format:
application/pdf
Permalink