ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 152 (1998), S. 75-89 
    ISSN: 1420-9136
    Keywords: Key words: Pulse width, source length.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract —The pulse width of the initial P wave was measured for three clusters of the aftershock sequence of the Patras (5.4 M S  ) July 1993 earthquake. The data set consists of pulse width measure ments of 250 microearthquakes recorded at a low-noise station of the University of Patras Seismological Network between 4-7-1993 and 1-8-1993. The statistical relation between the fault length and the earthquake magnitude was established for each one of the three clusters and is compared with other published relations. The relation also, between seismic moment and fault length was examined and showed a dependence upon the prevailing tectonic regime.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of seismology 2 (1998), S. 337-349 
    ISSN: 1573-157X
    Keywords: crustal propagation ; Discrete Wwavenumber ; Empirical Green's ; rupture propagation ; seismic source ; site effects ; strong
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract A damaging earthquake occurred on 14 July 1993 in Patras, Western Greece. The mainshock (local magnitude 5.1) was followed on the same day by two aftershocks of magnitudes 4.4 ML and 3.6 ML, respectively. The strong motion record of the mainshock is studied, based on the teleseismically determined seismic moment and focal mechanism. The Discrete Wavenumber (DW) and Empirical Green's Function (EGF) methods are used. The main conclusion is that the 1993 Patras mainshock had a complex S-wave group mainly due to structural (path and site) effect. However, some effects of the rupture stopping on the peak ground acceleration (0.2 g in the so-called S3 phase) cannot be ruled out. Two values of the source radius are suggested: R = 1.9 and 3.0 km. The strong motion record better agrees with R = 1.9 km. If the latter is true, the stress drop was of the order of 20 MPa, i.e., higher than often reported for comparable events in Western Greece. Regardless of the true source radius, the ratio of stress drops between the mainshock and aftershocks was about 1–2. The aftershock waveforms indicate significant lateral heterogeneities around Patras. Therefore, the ground-motion predictions of strong events in the area will remain highly non-unique until weak events from an immediate neighbourhood of the particular fault are recorded.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...