ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (10)
  • 1
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: A digital device has been developed to meter the current drain of a battery in ampere hours. The device consists of a voltage controlled oscillator (VCO), a frequency divider, an accumulator, and a liquid crystal display. A voltage proportional to load current is converted into a clock signal whose pulse rate is scaled by the frequency divider to the desired engineering units. Final output pulses are counted and displayed. The use of MOSFET and CMOS integrated circuits allows continuous battery-powered operation over a 3-month time period to an accuracy of +/- 2 percent. The instrument will find application where accurate monitoring of battery charge/discharge status is required over long time intervals.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 39th, Albuquerque, NM, May 2-6, 1993, Proceedings (A93-54351 24-35); p. 431-444.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: Aerodynamic wind tunnel tests at NASA Langley Research Center (LaRC) require accurate measurement of model attitude. Inertial accelerometer packages have been the primary sensor used to measure model attitude to an accuracy of +/- 0.01 deg as required for aerodynamic research. The calibration parameters of the accelerometer package are currently obtained from a seven-point tumble test using a simplified empirical approximation. The inaccuracy due to the approximation exceeds the accuracy requirement as the misalignment angle between the package axis and the model body axis increases beyond 1.4 deg. This paper presents the exact solution derived from the coordinate transformation to eliminate inaccuracy caused by the approximation. In addition, a new calibration procedure is developed in which the data taken from the seven-point tumble test is fit to the exact solution by means of a least-squares estimation procedure. Validation tests indicate that the new calibration procedure provides +/- 0.005-deg accuracy over large package misalignments, which is not possible with the current procedure.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 39th, Albuquerque, NM, May 2-6, 1993, Proceedings (A93-54351 24-35); p. 89-102.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-28
    Description: The NASA Langley 6 inch magnetic suspension and balance system (MSBS) requires an independently controlled bidirectional DC power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance coupled thyratron controlled rectifiers as well as AC to DC motor generator converters, is obsolete, inefficient, and unreliable. A replacement six phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full load efficiency is 80 percent compared to 25 percent for the resistance coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20 kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-4198 , L-16717 , NAS 1.15:4198
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-06-28
    Description: Precision analog signal conditioning electronics have been developed for wind tunnel model attitude inertial sensors. This application requires low-noise, stable, microvolt-level DC performance and a high-precision buffered output. Capacitive loading of the operational amplifier output stages due to the wind tunnel analog signal distribution facilities caused regenerative oscillation and consequent rectification bias errors. Oscillation suppression techniques commonly used in audio applications were inadequate to maintain the performance requirements for the measurement of attitude for wind tunnel models. Feedback control theory is applied to develop a suppression technique based on a known compensation (snubber) circuit, which provides superior oscillation suppression with high output isolation and preserves the low-noise low-offset performance of the signal conditioning electronics. A practical design technique is developed to select the parameters for the compensation circuit to suppress regenerative oscillation occurring when typical shielded cable loads are driven.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-4658 , L-17453 , NAS 1.15:4658
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-28
    Description: A newly developed technique for enhanced data reduction provides an improved procedure that allows least squares minimization to become possible between data sets with an unequal number of data points. This technique was applied in the Crew and Equipment Translation Aid (CETA) experiment on the STS-37 Shuttle flight in April 1991 to obtain the velocity profile from the acceleration data. The new technique uses a least-squares method to estimate the initial conditions and calibration constants. These initial conditions are estimated by least-squares fitting the displacements indicated by the Hall-effect sensor data to the corresponding displacements obtained from integrating the acceleration data. The velocity and displacement profiles can then be recalculated from the corresponding acceleration data using the estimated parameters. This technique, which enables instantaneous velocities to be obtained from the test data instead of only average velocities at varying discrete times, offers more detailed velocity information, particularly during periods of large acceleration or deceleration.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-4460 , L-17168 , NAS 1.15:4460
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-28
    Description: This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA PAPER 93-1560 , In: AIAA(ASME)ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference, 34th and AIAA/ASME Adaptive Structures Forum, La Jolla, CA, Apr. 19-22, 1993, Technical Papers. Pt. 4 (A93-33876 1; p. 2174-2183.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-28
    Description: This report presents a theoretical analysis of the dynamic effects of angular motion in yaw and pitch on model attitude measurements in which inertial sensors were used during wind tunnel tests. A technique is developed to reduce the error caused by these effects. The analysis shows that a 20-to-1 reduction in model attitude measurement error caused by angular motion is possible with this technique.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-4641 , L-17381 , NAS 1.15:4641
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: An investigation is conducted of application of optimal observer-based control laws derived using both pole-placement techniques and optimal linear regulator theory. Although a pole-placement-derived control law with optimal observer provides fast response and excellent noise rejection, its observer requires an electrical input proportional to the unknown skin friction force, which is unavailable. To overcome this limitation, an optimal linear regulator design is proposed which estimates the unknown force input and provides excellent noise rejection, at the expense, however, of significantly slower transient response.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: 1989 American Control Conference; Jun 21, 1989 - Jun 23, 1989; Pittsburgh, PA; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-08-28
    Description: A newly developed technique for enhanced data reduction provides an improved procedure that allows least squares minimization to become possible between data sets with an unequal number of data points. This technique was applied in the Crew and Equipment Translation Aid (CETA) experiment on the STS-37 Shuttle flight in April 1991 to obtain the velocity profile from the acceleration data. The new technique uses a least-squares method to estimate the initial conditions and calibration constants. These initial conditions are estimated by least-squares fitting the displacements indicated by the Hall-effect sensor data to the corresponding displacements obtained from integrating the acceleration data. The velocity and displacement profiles can then be recalculated from the corresponding acceleration data using the estimated parameters. This technique, which enables instantaneous velocities to be obtained from the test data instead of only average velocities at varying discrete times, offers more detailed velocity information, particularly during periods of large acceleration or deceleration.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 39th, Albuquerque, NM, May 2-6, 1993, Proceedings (A93-54351 24-35); p. 353-370.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: The original and improved designs for the Electromagnetic Position Sensor (EPS), an electronic instrument and associated multicoil sensor for the six-inch Magnetic Suspension and Balance System (MSBS) that measures aerodynamic model position, are compared. The EPS power amplifier and oscillator, input nulling stage, reference voltage generators, bandpass filter, summation and demodulation, and final stage are described. The effects of the MSBS and of model materials on the performance are addressed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Instrumentation Symposium; May 02, 1988 - May 06, 1988; Albuquerque, NM; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗