Publication Date:
2011-08-24
Description:
A brief description is presented of an optical flameout detection system under development at NASA Langley's 8-Foot High Temperature Wind Tunnel. The system design, theory of operation, and performance are addressed. The system can respond quickly to sudden changes in combustor light intensity and is a reliable indicator of flame activity within the combustor. Deviations of the system could provide more detailed information on various aspects of the combustion process.
Keywords:
INSTRUMENTATION AND PHOTOGRAPHY
Type:
In: International Instrumentation Symposium, 39th, Albuquerque, NM, May 2-6, 1993, Proceedings (A93-54351 24-35); p. 371-378.