ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Geometric and positional isomer separations  (1)
  • INSTRUMENTATION AND PHOTOGRAPHY  (1)
  • 1
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Calix[4]arene-tetramethyldisiloxane stationary phases ; Geometric and positional isomer separations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Poly(p-tert-butyldimethoxydipropyloxycalix[4]arene-tetramethyldisiloxane) (TBCX-TMDS) and poly(dimethoxydipropyloxycalix[4]arene-tetramethyl-disiloxane) (CX-TMDS), have been prepared and used as stationary phases for isothermal capillary gas chromatographic separations of positional isomers. Retention factors and separation factors for the isomers were measured. The isomers investigated were well-resolved on the two phases. Retention of all the solutes investigated is greater on TBCX-TMDS than on CX-TMDS, probably because of extra dispersive interactions of the solutes with thetert-butyl groups of the phase. Separation factors for closely-eluting isomer pairs are similar on the two phases. This seems to indicate either that the solutes are retained by non-inclusion processes or that if the isomer molecules do enter the cavity of the calixarene, i.e. the solute is retained by inclusion, thetert-butyl groups do not play a role in discriminating between the isomers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-27
    Description: A large area double scattering telescope for balloon-borne research is described. It measures the flux, energy and direction of 2-100 MeV neutrons and 0.5-30 MeV gamma rays. These measurements are made using time-of-flight and pulse height analysis techniques with two large tanks of mineral oil liquid scintillator. Results from Monte Carlo calculations of the efficiency, energy resolution and angular resolution are presented and the electronics implementation for the processing of 80 photomultiplier tubes signals will be discussed. The detector weighs 800 kg with a large part of this weight being the liquid scintillator (320 kg). It will be flown at 3 mbars for flight durations up to 40 hours. The first flight is planned for Spring, 1975.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...