ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Fundamental interpretation  (1)
  • Linearity between peak width and retention data  (1)
  • Retention time and separation efficiency  (1)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 124-128 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Series-coupled chemically differing columns ; Fundamental studies on the properties for basic theory started ; Retention time and separation efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Basic expressions are derived for both the retention time and the effective separation factor in serially coupled GC columns. The retention time is determined by two main parameters. The first is the fractional time spent by an unretarded solute in each column which, in turn, is determined by the relative column lengths and flow velocities through each column. The second parameter is the relative mass distribution coefficient of a particular solute in each column; a variable that can be adjusted by changing the relative temperatures of the columns. The expression for the effective separation factor relates the measured separation factor for the series combination to the separation factors on the individual columns, the fractional time spent by an unretarded peak in each column, as well as the relative values of the mass distribution coefficients of a particular solute on the different columns.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 41-46 
    ISSN: 0935-6304
    Schlagwort(e): Chromatography ; Theory ; Chromatographic systems analysis ; Real plate number ; Fundamental interpretation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The real plate number concept is interpreted in terms of the fundamental properties of a chromatograph. It is shown that the linear relationship between the total peak width at half height, (b0.5)T, t, and k is only an approximation of the more general linear relationship between (b0.5)2T, t and (1 + k)2. In the case where the relationship between (b0.5)T, t and k approaches linearity, it is concluded, firstly, that b0 = a, i. e., b0 is a column property and independent of extra-column phenomena and, secondly, that nreal=ntheor. When the relationship becomes non-linear, b0 is determined partly by extra-column phenomena, but not in terms of a useful relationship. It is concluded that it is unnecessary to introduce the parameters a, b0 and nreal, since they all have counterparts in the established theory of chromatography. These counterparts prove to be equally useful in the practical analysis of chromatographic systems.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 456-460 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Capillary ; Theory ; Linearity between peak width and retention data ; Evaluation of GC equipment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The linearity of the relationship between σT,t2 and (1 + k)2 is studied with the view of using it for the evaluation of GC equipment. Based on appropriate analytical expressions it is concluded that in general this relationship is not linear and that practical procedures for column evaluation should be developed that take this non-linearity into account.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...