ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 839-850 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Chemometry ; Fourier analysis ; Multicomponent mixture chromatograms ; PCB analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Aroclor and Aroclor mixture chromatograms obtained using temperature programmed high resolution capillary GC coupled with mass spectrometric selective detection have been investigated by Fourier analysis developed for the study of multicomponent chromatograms. The experimental autocorrelation function (EACF), i.e. peak shape and position correlation, showed a retention - structure pattern which could be associated with both the type of Aroclor and the ion used for selective ion monitoring (m/z value). In particular, o-m and m-m isomerization effects were singled out by EACF analysis. By fitting EACF with previously developed theoretical models, it was possible to characterize a specific Aroclor in terms of the number of PCB congeners present in it. The results obtained agreed closely with the typical Aroclor content. For the Aroclor mixture, the distribution of inter-distance between successive peaks was derived. The two first distribution moments obtained agreed with those derived from retention data reported in the literature. The consequences on the separation performance, i.e. the number of singlets, doublets, etc. in the chromatogram, are discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 327-332 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Separation performance ; Fourier analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple procedure is presented for determining separation performance of HRGC analysis of multicomponent mixtures. The procedure is based on the computation of Autocovariance Function (EACVF) from the digitized experimental chromatogram. Graphic inspection of the EACVF plot permits easy computation of the width value of the single component peak, σ; from the EACVF value at t=O the number of component in the mixture, m, can be simply derived. From these two basic quantities all the other chromatographic performance attributes can be calculated. The consistency of the procedure is tested for different chromatograms and compared with the more complex EACVF fitting method. Several features of the multicomponent chromatogram, overloading effects included, are directly detected.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...