ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1040-0397
    Keywords: XPS analysis ; Fluoride ; Ion selective electrode ; Surface analysis ; Hydroxide interference ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Lanthanum fluoride and cerium fluoride single crystals, used as the sensing membranes of the fluoride ion-selective electrode (F-ISE), were investigated for their hydroxide interference and surface reactions with OH- in high pH conditions. While these membranes show fast response and excellent Nernstian behavior over a wide concertration range in buffered F- solutions, they deviate from the theoretical slope at high pH. CeF3, in particular, exhibits a much larger deviation from the Nernstian slope and a substantially slower response to a F- activity change compared to LaF3. This larger deviation is due to more extensive and faster formation of hydroxo-complexes, with the release of a greater amount of the fluoride ion into the hydrated gel layer. The slower response of the CeF3 membrane after contact with OH- is due to the formation of CeIV oxide on the surface, which acts as a blocking layer to the exchange of F-.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗