ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Environment Pollution  (1)
  • sensitivity study  (1)
  • 1
    ISSN: 1573-0662
    Keywords: OH-radicals ; troposphere ; long path absorption spectroscopy ; sensitivity study ; formaldehyde ; measurements
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Geosciences
    Notes: Abstract Using long path UV absorption spectroscopy we have measured OH concentrations close to the earth's surface. The OH values observed at two locations in Germany during 1980 through 1983 range from 0.7×106 to 3.2×106 cm-3. Simultaneously we measured the concentrations of O3, H2O, NO, NO2, CH4, CO, and the light non methane hydrocarbons. We also determined the photolysis rates of O3 and NO2. This allows calculations of OH using a zero dimensional time depdendent model. The modelled OH concentrations significantly exceed the measured values for low NO x concentrations. It is argued that additional, so far unidentified. HO x loss reactions must be responsible for that discrepancy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: During October 19-20, 1991, one flight of the NASA Global Tropospheric Experiment (GTE) Pacific Exploratory Mission (PEM-West A) mission was conducted near Hawaii as an intercomparison with ground-based measurements of the Mauna Loa Observatory Photochemistry Experiment (MLOPEX 2) and the NOAA Climate Modeling and Diagnostics Laboratory (CMDL). Ozone, reactive nitrogen species, peroxides, hydrocarbons, and halogenated hydrocarbons were measured by investigators aboard the DC-8 aircraft and at the ground site. Lidar cross sections of ozone revealed a complex air mass structure near the island of Hawaii which was evidenced by large variation in some trace gas mixing ratios. This variation limited the time and spatial scales for direct measurement intercomparisons. Where differences occurred between measurements in the same air masses, the intercomparison suggested that biases for some trace gases was due to different calibration scales or, in some cases, instrumental or sampling biases. Relatively large uncertainties were associated with those trace gases present in the low parts per trillion by volume range. Trace gas correlations were used to expand the scope of the intercomparison to identify consistent trends between the different data sets.
    Keywords: Environment Pollution
    Type: Paper 96JD00213 , Journal of Geophysical Research (ISSN 0148-0227); 101; D9; 14,599-14,612
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...