ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Topics in catalysis 1 (1994), S. 95-102 
    ISSN: 1572-9028
    Keywords: Electro-catalysis ; metal deposition ; alloys
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract When Pt-Rh(100) alloy surface was exposed to NO or O2 at temperatures higher than 400 K, a characteristic p(3 × 1) LEED pattern appeared with segregation of Rh atoms on the surface. It was shown that when a Rh-deposited Pt(100) surface is heated in NO or O2 the same 5 × 10−8 Torr of H2 at room temperature, the p(3 × 1) pattern disappears but is readily recovered 5 × 10−8 Torr of H2 at room temperature, the p(3 × 1) pattern disappears but is readily recovered by exposing to O2 of 1 × 10−7 Torr at room temperature. The growth of a Rh-O overlayer on Pt layer is responsible for the formation of the p(3 × 1) structure on either the Pt-Rh(100) alloy or Pt(100) surface, and this peculiar surface may correspond to the active surface of the Pt-Rh catalyst for NO x reduction
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-0832
    Keywords: Cryptococcal antigen ; Eiken Latex ; Latex agglutination test ; Murine disseminated cryptococcosis ; Pastorex® Cryptococcus ; Pulmonary cryptococcosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract A latex agglutination test for cryptococcal antigen, the Eiken Latex test (Eiken, Tokyo, Japan), was compared with a monoclonal antibody-based agglutination assay, Pastorex® Cryptococcus (Diagnostics Pasteur, Marneur-la-Coquette, France). In a murine model of disseminated cryptococcosis, the kinetics of the antigen titers by the Eiken Latex were similar to those by the Pastorex® Cryptococcus, but sensitivity was much higher. In HIV-negative patients with pulmonary cryptococcosis, a cryptococcal antigen was detected in 6 of 10 patients by the Eiken Latex test and in only 3 of those patients by the Pastorex® Cryptococcus. The results indicate that the Eiken Latex is more sensitive for the detection of the cryptococcal antigen, even in non-disseminated cryptococcosis. The sensitivity and specificity of the Eiken Latex were examined using 195 sera from 25 patients with pulmonary cryptococcosis and 170 patients with non-cryptococcosis. The cutoff value of ≥ 1:8 showed a sensitivity of 76% (19/25) and a specificity of 98.9% (168/170).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...