ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: supercritical fluid chromatography ; experimental design optimization ; Diesel fuel ; group-type analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---An optimization procedure is presented for group-type analysis of diesel fuel by supercritical fluid chromatography using packed silica column and a mixed mobile phase. A set of five responses, four values of resolution of a performance mixture and analysis time, was modeled using a Doehlert matrix for experimental design. Optimized experimental conditions for the five responses were obtained from a response surfaces optimization, taking into account various constraints on SF6 content in mobile phase and analysis time. The predicted and experimental resolutions were in good agreement for the different optimized conditions and one of them was selected to for application to a given diesel fuel for comparison with the results obtained by SFC using pure CO2 and by HPLC. The conditions found in this study provide an alternative method for the determination of mono-, di-, and polyaromatic compounds in middle distillates.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 175-180 
    ISSN: 0935-6304
    Keywords: Supercritical Fluid Extraction (SFE) ; supercritical fluid chromatography ; solid trapping ; solvent trapping ; polymeric phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---One way of collecting extracted analytes after a supercritical fluid extraction (SFE) is to pass the depressurized fluid through a trap composed of a solid adsorbent. The influence of the adsorbent nature on the trap efficiency has been studied. First, the retention factors of each compound of a polarity test mix (tetracosane, naphthalene, fluoranthene, acetophenone, N,N-dimethylaniline, 2-naphthol, decanoic acid) have been determined on five high specific area (greater than 800 m2/g) polymeric phases by supercritical fluid chromatography (SFC). The comparison of this values with those obtained on octadecyl silica (ODS) showed that polymeric phases have the greatest retention power. After that, the efficiency of a solid trap filled with the greatest retention power polymeric adsorbent was evaluated by using pure carbon dioxide and 2.5%, 5%, 10%, and 20% methanol-modified carbon dioxide. As expected, this trap permitted a quantitative collection of all the former compounds even when a content as high as 10% of methanol was implemented. A solid trap filled with ODS adsorbent allowed quantitative collection of all the compounds only at a methanol content lower than 2.5%.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 457-463 
    ISSN: 0935-6304
    Keywords: Supercritical Fluid Extraction (SFE) ; ultrasonication extraction ; gas chromatography ; derivatization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Supercritical fluid extraction (SFE) of alkyl alkylphosphonofluoridates and dialkyl alkylphosphonates from painted plates was investigated. It was found that SFE recoveries compared favorably with conventional solvent sonication results. Stability studies of the samples were carried out over a period of two months. This investigation showed that the concentration of phosphonofluoridates decreased over a long period.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...