ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Detection limits ; Trace analysis ; Narrow bore columns ; Wide bore columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The need for faster and more efficient separations of complex mixtures of organic compounds by gas chromatography has led to the development of small inner diameter open tubular columns. Owing to their decreased plate height, extremely narrow peaks are obtained. When differently sized columns with equal plate numbers are compared, injection of a fixed amount of a solute will give the highest detector signals for the smallest bore columns. When P is defined as the ratio of the column inlet and outlet pressures, it can be seen from theory that under normalized chromatographic conditions the minimum detectable amount (Qº) for a mass flow sensitive detector increases proportionally to the square of the column diameter for P = 1. In the situation of greater interest in the practice of open tubular gas chromatography where P is large, a linear relationship is derived between Qº and the column diameter.It is a widespread misunderstanding, however, that narrow bore capillary columns should be used for this reason in trace analysis. If a fixed relative contribution of the injection band width to the overall peak variance is allowed, a decreased plate height drastically restricts the maximum sample volume to be injected. It is shown that the minimum analyte concentration in the injected sample (Cº) is inversely proportional to the column inner diameter when a mass flow sensitive detector is used. For actual concentrations less than Cº, sample preconcentration is required. The effect of peak resolution and selectivity of the stationary phase in relation to Cº and Qº will be discussed as well. The validity of the given theory is experimentally investigated. Minimum analyte concentrations and minimum detectable amounts are compared using columns with different inner diameter.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 845-848 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; GC/MS ; Theory ; Ceparation speed ; Detection limits ; Identification limits ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...