ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science: Macromolecular Reviews 16 (1981), S. 295-366 
    ISSN: 0076-2083
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 37 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science 59 (1962), S. 301-316 
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Nuclear magnetic relaxation times have been studied in some polymer liquids and solutions. The nonexponential decay of the transverse magnetization has been ascribed to the distribution of molecular weights. The use of such measurements as a means of determining average molecular weights and distributions is discussed. A preliminary application of this use is made for polyethylene. The implications of nuclear magnetic relaxation measurements are discussed in terms of molecular motional processes of the polymer chains.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A: General Papers 1 (1963), S. 1709-1720 
    ISSN: 0449-2951
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Various self-diffusion and nuclear relaxation experiments are reported for a polyisobutylene of rather low molecular weight, in bulk and in solution. In the bulk, the self-diffusion coefficient obeys the Arrhenius relation, yielding an activation energy of 5.5 kcal./mole. In solution the activation energies are lower, approaching the value for the solvent at low concentration. The self-diffusion coefficient of the polymer at infinite dilution is 1.2 × 10-5 cm.2/sec. in CS2 and 0.44 × 10-5 cm.2/sec. in CCl4. The ratio is close to the inverse ratio of the solvent viscosities. Measurements of self-diffusion of the solvent have been made for cyclohexane in polyisobutylene. A simple interpretation of the data in terms of Stokes-Einstein models yields molecular dimensions which are too small by a factor of two or three.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-08-28
    Description: A short-range communication system includes an antenna, a transmitter, and a receiver. The antenna is an electrical conductor formed as a planar coil with rings thereof being uniformly spaced. The transmitter is spaced apart from the plane of the coil by a gap. An amplitude-modulated and asynchronous signal indicative of a data stream of known peak amplitude is transmitted into the gap. The receiver detects the coil's resonance and decodes same to recover the data stream.
    Keywords: Communications and Radar
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-07-13
    Description: Goals Determine Out-Link FSK Bandwidth Develop FSK Outlink Transmitter Develop Wideband Outlink FSK Receiver Develop OOK In-Link Transmitter Develop OOK In-Link Receiver Marry Out-Link & In-Link Components Outlink FSK Bandwidth preliminary inlink transmitter were accomplished in Summer 1995 visit. The calculation of FSK bandwidth is repeated in these notes. Spectrum analyzer measurements of the actual FSK spectrum agree well with the calculations. The goal to develop a wideband FSK receiver for outlink data was given first priority for end of Summer 1996 completion. The goal of developing OOK inlink transmitter and receiver system components and interfacing all outlink and inlink components into an operating closed loop prototypical system was given a December 1, 1996 completion date.
    Keywords: Communications and Radar
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-13
    Description: This final report encapsulates the accomplishments of the third year of work on an Advanced Biotelemetry System (ABTS). Overall MU/ABTS project objectives are to provide a biotelemetry system that can collect data from and send commands to an implanted biotransceiver. This system will provide for studies of rodent development in space. The system must be capable of operating in a metal animal cage environment. An important goal is the development of a small, "smart", micropower, -channel data output and single channel command implantable biotransceiver with eight input capabilities with the flexibility for easy customization for a variety of physiologic investigations. The NASA Ames/Marquette University Joint Research work has been devoted to the system design of such a new state of the art biotelemetry system, having multiple physiologic inputs, and bi-directional data transfer capabilities. This work has provided a successful prototype system that connects, by two-way radio links, an addressable biotelemetry system that provides communication between an animal biotelemeter prototype and a personal computer. The operational features of the prototype system are listed below: Two-Way PCM Communication with Implanted Biotelemeter Microcontroller Based Biotelemeter Out-Link: Wideband FSK (60 kbaud) In-Link: OOK (2.4 kbaud) Septum Antenna Arrays (In/Out-Links) Personal Computer Data Interface The important requirement of this third year's work, to demonstrate two-way communication with transmit and receive antennas inside the metal animal cage, has been successfully accomplished. The advances discussed in this report demonstrate that the AAH cage antenna system can provide Out-link and In-link capability for the ABTS bi-directional telemetry system, and can serve as a benchmark for project status.
    Keywords: Communications and Radar
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-13
    Description: This final report encapsulates the accomplishments of the third year of work on an Advanced Biotelemetry System (ABTS). Overall MU/ABTS project objectives are to provide a biotelemetry system that can collect data from and send commands to an implanted biotransceiver. This system will provide for studies of rodent development in space. The system must be capable of operating in a metal animal cage environment. An important goal is the development of a small, "smart", micropower, implantable biotransceiver with eight-channel data output and single channel command input capabilities with the flexibility for easy customization for a variety of physiologic investigations. The NASA Ames/Marquette University Joint Research work has been devoted to the system design of such a new state of the art biotelemetry system, having multiple physiologic inputs, and bi-directional data transfer capabilities. This work has provided a successful prototype system that connects, by two-way radio links, an addressable biotelemetry system that provides communication between an animal biotelemeter prototype and a personal computer. The operational features of the prototype system are: (1) two-way PCM communication with implanted biotelemeter; (2) microcontroller based biotelemeter; (3) out-link: wideband FSK (60 kBaud); (4) in-link: OOK (2.4 kbaud); (5) septum antenna arrays (In/Out-Links); and (6) personal computer data interface. The important requirement of this third year's work, to demonstrate two-way communication with transmit and receive antennas inside the metal animal cage, has been successfully accomplished. The advances discussed in this report demonstrate that the AAH cage antenna system can provide Out-link and In-link capability for the ABTS bi-directional telemetry system, and can serve as a benchmark for project status. Additions and enhancements to the most recent (April 1997) prototype cage and antenna have been implemented. The implementation, testing, and documentation was accomplished at the Biotelemetry Laboratory at Marquette University with Out-Link (slot) antenna design assistance was provided.
    Keywords: Communications and Radar
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-07-13
    Description: The report discusses: (1) Determination Out-Link Frequency Shift Keying (FSK) Bandwidth. (2) Development FSK Out-link Transmitter. (3) Development Wideband Out-link FSK Receiver. (4) Development OOK In-Link Transmitter. (5) Development OOK In-Link Receiver. and (6) Marry Out-Link & In-Link Components. Out-link FSK Bandwidth preliminary in-link transmitter were accomplished in Summer 1995 visit. The calculation of FSK bandwidth is repeated in these notes. Spectrum analyzer measurements of the actual FSK spectrum agree well with the calculations.
    Keywords: Communications and Radar
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-07-13
    Description: The closed loop prototype has operational bi-directional wireless links. The Wideband PCM-FSK receiver has been designed and characterized. Now that both links function, communication performance can be addressed. For example, noise problems with the received outlink signal that caused the PC program to lockup were just recently revealed and minimized by software "enhancements" to the Windows based PC program. A similar problem with inlink communication was uncovered several days before this report: A noise spike or dropout (expected events in the animal Habitat) caused an interrupt to the implant microcontroller which halted outlink transmission. Recovery of outlink transmission did not reliably occur. The problem has been defined and implant software is being modified to better recognize noise from data by changing the timing associated with valid data packet identification and by better utilizing the error flags generated by the microcontroller's SCI circuits. Excellent inlink performance will also require improvements in the implant's receiver. The biggest performance improvement can be provided by antenna design for the Habitat. The quarter wavelength whip antennas used with the demo prototype inlink leave much to be desired.
    Keywords: Communications and Radar
    Type: NASA/CR-1997-205847 , NAS 1.26:205847
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...