ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1040-0397
    Keywords: Electrocatalytic oxygen sensor ; Polymer film modified electrode ; β-Cyclodextrin polymer film ; Carboxymethylated β-cyclodextrin polymer film ; Cobalt tetraphenylporphyrin ; Cobalt tetrakis-(N-methylpyridyl)porphyrin ; Cobalt tetrakis-(4-sulfonatophenyl)porphyrin ; Cyclic voltammetry ; Voltammetry at rotating ring and ring-disk electrode ; Piezoelectric microgravimetry ; Electrochemical quartz crystal microbalance ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New oxygen sensors, based on polymer film modified electrodes, were prepared and applied for electrocatalytic determination of dioxygen dissolved both in aqueous and aqueous-organic, mixed solvent solutions. The sensors were made of gold electrodes coated with thin polymer film matrices of either neutral β-cyclodextrin polymer, β-CDP, or cation-exchange carboxymethylated β-cyclodextrin polymer, β-CDPA, hosting electrocatalytically active centes of cobalt tetraphenylporphyrin, (TPP)Co, cobalt tetrakis-(N-methylpyridyl)porphyrin, (TMPyP)Co, or cobalt tetrakis-(4-sulfonatophenyl)porphyrin, (TPPS)Co. Films were cast from aqueous solutions of the respective β-cyclodextrin prepolymer, cobalt porphyrin and glutaric dialdehyde used as the polycondensation crosslinking reagent. Catalytic dioxygen electroreduction at the electrode coated with polymer film hosting the cobalt porphyrin catalyst involves two electrons and two protons resulting in the formation of hydrogen peroxide. The sensitivity of dioxygen determination largely increases in the order (TPPS)Co 〈(TPP)Co〈(TMPyP) Co for the β-CDPA film electrodes, being governed by ion-exchange equilibria with respect to the cobalt porphyrin catalyst, while it depends only slightly on the nature of the cobalt porphyrin catalyst for the β-CDP film. The catalytic rate constant of the dioxygen reaction with the cobalt porphyrin catalyst in the film was estimated as k ≍ 2 × 104 M-1 s-1 being larger than those for either adsorbed or electropolymerized catalyst at the electrode and close to that for the catalyst present in solution. The performance of the sensors is presented with respect to the detection signal linearity, reproducibility, long-term stability, reversibility regarding dioxygen binding and response time.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...