  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 193-204 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method which involves the use of tandem mass spectrometry (MS/MS) for the identification of drug metabolites has been demonstrated with a triple quadrupole mass spectrometer. The method is based on the fact that metabolites usually retain various substructures of the original drug molecule. MS/MS is capable of rapidly identifying molecules with characteristic substructures without prior separation. It is shown that this method makes it possible to postulate possible drug metabolite structures rapidly and systematically without the use of standards. The MS/MS method, as it was applied to the identification of the metabolites of a new antiepileptic drug, zonisamide, is discussed. In this case it was possible to identify isomeric metabolites due to their differences in vaporization times off the probe and their different daughter spectra. The complementary uses of the neutral loss and parent scans for the determination of the site of metabolism is demonstrated. A new figure of merit, the limit of identification, is introduced. The amount of the epoxide metabolite of carbamazepine necessary for its reliable identification in urine was shown to be 0.4 ng/μl. The application of various techniques to confirm preliminary findings with this MS/MS method are described.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 29 (1994), S. 329-332 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 573-578 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Effects from higher order non-linear resonances, ‘black canyons’, have been observed for ions stored within the quadrupole ion-trap mass spectrometer. At specific qz values, higher-order field effects were observed to cause decreased intensity of chemical ionization (CI) reagent ions, due to ineffcient storage, as well as collision-induced dissociation. Efects have been observed, whether or not the CI reagent ions are mass-selected, and exibit increased severity with longer storage times. Previous reports have shown ‘black holes’ due to inefficient storage of product ions in tandem (MS/MS) spectra, but have reported no such effects in normal mass spectra. Without employing resonant excitation, higher-order field effects were investigated and found to occur continuously along iso-βz lines for βz = 1/3, 1/2, and 2/3. Described in this paper are the directs from higher-order fields on ions stored at specific az values, and indirec effects by those ions. Also described in this paper is new evidence for ‘black canyons’ occurring at βz = 1/3 at negative az values.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic/mass spectrometric method based on the use of short capillary gas chromatograph columns (3-5 m) and electron ionization mass spectrometry has been optimized and evaluated for the determination of underivatized anabolic steroids. The short-column gas chromatographic/mass spectrometric method was shown to result in short analysis times and to require minimal sample preparation, but suffered from some loss in sensitivity and chromatographic resolution compared with conventional gas chromatographic/mass spectrometric techniques for derivatized steroids. Therefore, short-column gas chromatographic conditions were optimized to maximize the sample transfer efficiency (sensitivity) from the gas chromatograph into the ion source of the mass spectrometer, while maintaining chromatographic integrity and minimizing thermal decomposition. Mass spectrometric conditions were optimized to maximize ionization efficiency with respect to the intensity of the molcular ion and degree of fragmentation such that positive identication of each steroid could be made based on the resulting mass spectra. Under optimized conditons, we have shown that underivatized anabolic steroids spiked into urine samples can be determined at low-nanogram levels using short-column chromatography/full-scan electron ionization mass spectrometry.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 23 (1994), S. 131-139 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Short-column (3.5 m) gas chromatography (GC)/tandem mass spectrometry (MS/MS) has been investigated for the detection of structurally related, underivatized anabolic steroids in urine. The approach described here demonstrates the ability to rapidly and qualitatively detect underivatized anabolic steroids in spiked urine matrices. In this approach, underivatized steroids are determined using a short-column GC separation, ionized by positive ion chemical ionization, and detected by selected reaction monitoring MS/MS. This approach permits positive identification of underivatized anabolic steroids based on retention time and the production of characteristic product ions. Preliminary detection limits studies in spiked urine samples showed quantitative results between 2 and 40 ng steroid per milliliter of urine. The potential advantages of this approach compared to present screening methods based on conventional (30 m) GC/MS are its rapidity and selectivity. Reliable qualitative identification can be performed with a short-column GC/MS/MS analysis of less than 6 min with a reduction in sample preparation time due to the elimination of the derivatization step.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 760-764 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The effect of the radial and axial dimensions on the Mathieu stability diagram (in terms of DC and RF voltages) is discussed with relation to the ‘stretched’ geometry employed in the Finningan MAT quardrupole ion-trap mass spectrometer (ITMS). Equations are presented for the conversion of the Mathieu au and qu parameters to DC voltages and RF voltages, respectively, and vice versa on the ITMS. A TURBOBASIC program is discussed which will provide data for graphing of a stability diagram in (RF, DC) space. Experimentally determined boundaries of the stability diagram are in good agreement with an approximate model for the stretched trap.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1076-5174
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A hydride Meisenheimer complex of 2,4,6-trinitrotoluene (TNT) (TNTH-) was synthesized using tetramethylammonium octahydroborate. TNT and TNTH- (as the tetramethylammonium salt) were analyzed by direct exposure probe mass spectrometry using electron impact (EI), chemical ionization (CI) and negative-ion chemical ionization (NCI). For further identification, the ions of the mass spectra were investigated using tandem mass spectrometry with collision-induced dissociation (CID). Although the EI mass spectra of both compounds were similar, the CID mass spectra of the ions at m/z 227 (M+ of TNT) of the two compounds showed large differences in daughter ion abundances. A major difference between the two compounds also appeared in their CI methane mass spectra. Two abundant ions, at m/z 183 and 198, appeared only in the CI mass spectrum of TNNH-. CID parent ion scans showed that the origin of these two ions was not the m/z 227 ion. We suggest that these ions are formed by chemical reactions of the complex on the surface of the heated probe tip, followed by ionization. These reactions, probably a reduction process forming m/z 198 and hydrolysis forming m/z 183, occur preferentially in TNTH-, the already reduced form of TNT. Formation of the ions at m/z 183 and 198 was also observed in the liquid chromatography particle beam CI mass spectrum of TNTH-.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Mass Spectrometry Reviews 2 (1983), S. 1-45 
    ISSN: 0277-7037
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1984), S. 104-105 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 24 (1989), S. 875-884 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Under electron ionization (EI) conditions, porphyrins yield unusually high intensities of doubly charged molecular and fragment ions. These doubly charged ions offer unique opportunities for the structure elucidation of porphyrins by tandem mass spectrometry (MS/MS). First, they fragment to a greater extent than the corresponding singly charged ions under both EI/MS and EI/MS/MS conditions. Second, doubly and singly charged porphyrin ions often fragment via different pathways, and can therefore yield different structural information. This paper describes several ways in which analyses of doubly charged porphyrin ions with a triple quadrupole tandem mass spectrometer can be useful in structure elucidation of porphyrins. The effect of the metal atom on the fragmentation of metalloporphyrins in an EI source is demonstrated by correlating the extent of doubly charged fragment ion formation to a stability index. Doubly charged porphyrin ions are shown to yield predominantly doubly charged daughter ions upon collisionally activated dissociation (CAD), and are also shown to fragment to a greater extent than corresponding singly charged porphyrin ions. Advantages and disadvantages of doubly charged porphyrin ion MS/MS for structure elucidation are discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability