ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 53 (1997), S. 332-338 
    ISSN: 0006-3592
    Keywords: α-hydroxynitrile lyase ; cassava ; cyanogenesis ; cyanohydrin ; Escherichia coli expression vector ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The coding sequence of the cyanogenic α-hydroxynitrile lyase gene of Manihot esculenta Crantz (cassava) was cloned in the plasmid vector pMal-c2 and expressed in Escherichia coli strain JM105. DNA sequencing showed that the recombinant plasmid contained the same sequence as the cDNA clone pHNL10. Peptide sequencing of the recombinant protein showed that the N-terminus was heterogeneous, with either four or six additional amino acid residues compared with the native protein. Circular dichroism spectra indicated similar secondary structure contents for both proteins. Enzyme assays showed that specific activity of native and recombinant proteins were 0.24 and 0.26 mmol CN-/mg/min, respectively; that both proteins had optimal activity at 40°C and pH 5.5; and that both proteins were inhibited by the serine protease inhibitor phenyl-methane sulfonyl flouride (PMSF). Isoelectric focusing of native and recombinant protein revealed multiple isoforms for both proteins; the recombinant protein had a more basic mean isoelectric point (pl) (5.1) than the native protein (4.5). © 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 53: 332-338, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0887-624X
    Keywords: oligocyclosiloxanes ; hydrosilation ; heptamethylcyclotetrasiloxane ; siloxane redistribution ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preparation of oligocyclosiloxanes via hydrosilation reactions has been investigated. Hydrosilation reactions employing heptamethylcyclotetrasiloxane and vinyl-containing silanes and siloxanes yielded a variety of oligocyclosiloxanes with various numbers of cyclosiloxane rings connected through tri-, tetra-, penta-, hexa-, hepta-, or octafunctional junctions. The oligocyclosiloxanes were characterized by gas chromatography, IR spectroscopy, 29Si-, 1H-, and 13C-NMR spectroscopy, elemental analysis, and vapor phase osmometry. The polycyclics were redistributed with hexamethyldisiloxane and the resulting fragments analyzed by gas chromatography. All results were consistent with the formation of isomeric oligocyclosiloxanes due to a lack of absolute regioselectivity of the hydrosilation reaction. © 1993 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 615-621 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The collisionally activated decomposition of [M + H]+ ions, generated by fast atom bombardment (FAB) of glutathione conjugates, has been studied by tandem mass spectrometry (MS/MS) using hybrid sector/quadrupole instruments. Abundant fragments of diagnostic utility were present in the daughter ion spectra. Common fragmentation modes were observed but their relative importance was strongly dependent on the nature of the conjugated species. As an example of a general approach to the characterization of glutathione conjugates in biological samples, the acetaminophen-glutathione conjugate was identified in rat bile, following coadministration of (2H0)- and (2H3)acetaminophen, using the experimental sequence: (i) conventional FAB mass spectrometric analysis, (ii) MS/MS using constant neutral loss (129 u) scanning to identify parent ions corresponding to glutathione conjugates, (iii) MS/MS to yield daughter ion spectra of parents so identified and corresponding to (2H0)- and (2H3)-labeled conjugates.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 54-58 
    ISSN: 0935-6304
    Keywords: High resolution capillary GC ; High resolution GC-MS ; Zeolite ZSM-5 ; Copaiba tree (Copaifera officinalis) ; Copaiba oil ; Fuel oil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The oil extracted from the trunk of the copaiba tree (Copaifera officinalis) is composed of sesquiterpenes, C15H24, and a small amount (〉7 %) of sesquiterpenols, C15H26O; these were identified from their Kováts indices and mass spectra. The use of zeolites in the catalytic transformation of this renewable source of hydrocarbons is of interest in the search for new chemicals and ecologically clean fuels. Oil samples from copaiba trees growing in Colombia's Oriental Plains were circulated over zeolite ZSM-5 in a continuous flow fixed-bed micro reactor at 225, 265, and 325°C, for 1 h and subsequently analyzed by HRGC and GC-MS. Whereas only thirty four sesquiterpenes were identified in the original oil, over two hundred compounds were found in the product of the treatment of copaiba oil with zeolite ZSM-5. This complex mixture of sesquiterpenes, light aromatic compounds, and indene and naphthalene derivatives resulted from reactions such as isomerization, hydrogenation, cracking, and dehydrogenation with and without cracking. The amount of cracking products and aromatic compounds increased with reactor temperature but decreased with catalyst aging.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The need for alternatives to autogenous bone grafts is widely recognized. This study compared the torsional strength of canine femora 1 year after grafting with one of three forms of a collagen/hydroxyapatite/tricalcium phosphate bone grafting material (COLLAGRAFT15), autogenous bone, or no graft. The groups were compared to each other and to the unoperated contralateral femora. Results of torsional testing were evaluated for torsional strength, torsional displacement, total energy to fracture and White fracture mode. Data analysis showed lower torsional strength of the operated vs. unoperated femora with the exception of morsellized COLLAGRAFT15 material, which had higher strength. However, the only difference in the operated groups was that the morsellized COLLAGRAFT15 had greater strength than several groups including the autogenous bone group. There was no difference found in angular displacement between any of the groups. However, there was a difference in the energy to fracture in both strip forms of the COLLAGRAFT15. The final conclusion is that in this model, grafting with COLLAGRAFT15 provided torsional properties at one year postoperatively at least equivalent to autogenous bone. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 409-413 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Gas chromatography/electron capture negative ion mass spectrometry of eicosanoids, as pentafluorobenzyl (PFB) ester, methyl oxime (where applicable), trimethylsilyl (TMS) ether derivatives, is reported using a double-focusing instrument of trisector configuration. Sub-picogram detection limits were observed for prostaglandins E1, E2 and F2α during selected ion monitoring (SIM) of [M — PFB]- ions. Selected reaction monitoring (SRM) of [M — PFB]- → [M — PFB — TMSOH]-, occurring in the first field-free region, was of modest sensitivity, reflecting the stability of the [M - PFB]- ions. The leukotriene B4 (LTB4) derivative was successfully analyzed by SIM at the low-picogram level. In this instance, the fragmentation [M — PFB]- →[M — PFB — TMSOH] occurred in high yield in the first field-free region. The advantageous improvement in selectivity of detection that may be achieved with SRM was evident during the analysis of a serum extract for LTB4.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 217-221 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Nanogram quantities of glucuronic acid conjugates of GR117289 in rat and dog bile have been analysed by semi-microbore high-performance liquid chromatography (HPLC)/ionspray mass spectrometry with on-line UV diode array detection. The determination of drug metabolites in bile has often proved problematical due to the large number of endogenous components in this biological matrix, in particular the bile acids. Semi-microbore HPLC is useful for concentrating small quantities of material and, in combination with an on-line diode array detector, for distinguishing between drug related and endogenous components. A novel angiotensin II receptor antagonist, GR117289, had proved difficult to analyse by thermospray mass spectrometry because of its thermal lability. The use of the less thermally dependent technique of ionspray mass spectrometry allowed the characterization of nanogram quantities of glucuronic acid metabolites of GR117289 in bile.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 555-560 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The application of fast-atom bombardment mass Spectrometry and collisiorutlly induced dissociation with mass-analysed ion kinetic energy (CID/MIKE) Spectrometry of representative inositol mono-, bis- and trisphos-phates is described. Based on their CID/MIKE spectra, inositol polyphosphates containing vicinal phosphate groups could be distinguished from isomers in which adjacent phosphate groups were absent. The potential value of this procedure in studies of the biochemistry of intracellular second messengers is discussed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 53 (1994), S. 485-496 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A new route (“direct forming”) was developed for forming dense PBI shapes from PBI powder. The new process affords the possibility of automated PBI powder shaping (“cold compaction”) and densification in batches of multiple parts by a “powder-assisted hot isostatic pressing” process. Direct forming is a more productive alternative to hot compression molding. Two developments enable PBI direct forming: (1) the discovery that PBI powders that are porous and plasticized with moisture can be shaped by compaction at ambient temperatures (cold-compacted), and (2) a finding that cold-compacted shapes can be densified in large batches by a powder-assisted hot isostatic pressing. The porous PBI powder is formed from PBI in solution by a spray-precipitation process. When plasticized with moisture, this powder is cold-compactible to PBI shapes with densities up to 94% of that of ultimate density of PBI. These shapes, which have sufficient strength to be handled, are then further consolidated via powder-assisted hot isostatic pressing to shapes with excellent thermal and mechanical properties and densities of about 99% of the ultimate. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 20 (1980), S. 1093-1096 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Over the past several years the semiconductor industry has placed major efforts into replacing wet processes with dry processes in fabricating electronic devices. Plasma photoresist stripping, plasma cleaning, and other dry etching techniques have replaced wet methods in many product lines. One area that has received little mention but which is vital toward achieving a totally dry manufacturing process is the dry development of photoresist. One production applicable plasma developable photoresist (PDF) process, using a proprietary resist formulation, is reported. Plasma process characterization, such as end point detection, development latitude, and mechanism are discussed. Included also are development temperature, batch film uniformity, and resolution currently obtainable with the PDF process.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...