ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Interactions between mononucleoside and dinucleoside phosphates containing adenine and/or cytosine and L-tryptophan have been studied at low pD by proton magnetic resonance (pmr) spectroscopy. The results of those studies indicate that, despite extensive protonation of ring positions, and resulting electrostatic repulsion, ring stacking does occur between both like and unlike molecules. Geometries for stacked complexes are proposed and the extent of complex formation between L-tryptophan and adenosine or cytidine in 3′ or 5′ esterified positions is discussed qualitatively.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 21 (1987), S. 683-700 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study examines the interaction of human low density lipoprotein (LDL) with a select group of biomedical polymers. The adsorption characteristics of LDL on cured filler-free poly(dimethyl Siloxane) (C-PDMS), Biomer, Cardiomat 610, Kraton 1650, poly(hydroxyethyl methacrylate) (PHEMA) and glass are presented. Adsorption of LDL to charged hydrophilic glass control surfaces occurred rapidly, reaching plateau concentrations within one minute (0.19 ± 0.01 ug/cm2). Adsorption of LDL to polymer surfaces appeared to be dependent upon both the polymer hydrophobicity (or apolar nature), and flexibility (or dynamic nature) at the interface. Increased surface concentrations were observed for Biomer (0.32 ± 0.01 ug/cm2) as well as other polymers which exhibited both hydrophobic and elastomeric próperties. Temperature changes between 25°C and 37°C were found to significantly influence the surface concentration of LDL on Biomer (0.16 ± 0.01 ug/cm2 at 25°C versus 0.32 ± 0.01 ug/cm2 at 37°C). A lipid core phase transition at 36°C was believed to be responsible for the temperature influence. Preliminary competitive adsorption studies of LDL with albumin (HSA) and serum on silicone surfaces suggests that LDL adsorption occurred rapidly and preferentially (0.25 ± 0.01 ug/cm2 for LDL alone; 0.33 ± 0.01 ug/cm2 for LDL + HSA; 0.15 ± 0.01 ug/cm2 LDL + serum). Preliminary studies on the role of LDL in calcification were not conclusive. It can be concluded that LDL adsorption is dependent upon polymer hydrophobicity, flexibility and temperature. Competitive adsorption experiments suggests that LDL may have substantial influence on protein adsorption.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 65-76 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A comprehensive protocol is presented for the in vivo evaluation of soft tissue foreign body reactions to surgical implants. A number of methods of evaluation and quantitation of the tissue reaction to implants are presented and discussed. A strong plea is made for semi-quantitation of tissue reactions, rather than relying on subjective, qualitative methods.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 199-211 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A brief discussion is presented of some of the problems and artifacts inherent in the testing of soft tissue reactions to artificial implants. The process of inflammation and wound healing is presented. The various factors affecting the foreign body reaction (chemical, mechanical, geometrical, and others) are discussed. The cellular components of the foreign body reaction are described and the sequential cellular changes that may occur as a result of implanting an artificial device are examined. The foreign body reaction should be considered as a chronic inflammatory response.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...