ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 4 (1958), S. 346-350 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This paper deals with the dispersion of one immiscible liquid in another (water in kerosene) by means of an orifice mixer. The degree of mixing was determined by measuring the area per unit volume of the dispersed phase. The area was measured with a photoelectric device, which had been calibrated photographically. The interfacial area formed at high Reynolds numbers (10,000 to 45,000, based on the diameter of the orifice) was found to increase with increases in both the volume fraction of water in the water-kerosene mixture and the change in kinetic energy across the orifice. In addition, other aspects such as the rate of coalescence of the dispersed phase downstream from the orifice are treated.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 5 (1959), S. 319-324 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The formation of air bubbles at constant pressure at submerged orifices was investigated for several liquids. The frequency of formation of the bubbles was determined by the use of a stroboscope, and the rate of gas flow was measured with conventional rotameters. Several orifices having diameters ranging from 0.0794 to 0.397 cm. were employed, and the gas flow rate was varied from about 0.1 cc. (at standard conditions)/sec. to about 150 cc./sec. It was found that the formation of bubbles could be correlated with the physical variables of the system by the application of Newton's second law of motion to the bubble at the instant just prior to its release from the orifice.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1149-1156 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Recombinant human bone morphogenetic protein- (rhBMP-) can be used to enhance the repair of congenital or acquired bone pathologies when formulated in the appropriate carrier. Poly [D, L-(lactide-co-glycolide)] (PLGA) has been shown to be an effective carrier of rhBMP-. We investigated several particle sizes PLGA and several doses of rhBMP- in a rat orthotopic model. We also investigated the effects of a fibrinolytic inhibitory agent, epsilon aminocaproic acid (EACA), on the healing response. Our data indicate that higher doses of rhBMP- resulted in increased failure torque (408 ± 70 N-mm or 60% of the intact value) and higher incidence of union (100%). The induced bone in femurs treated with the smaller particle size PLGA achieved the greatest torsional stiffness and strength. The presence of rhBMP- was necessary for new bone to form, but the presence of EACA did not change these results; the use of the PLGA carrier appeared to increase bone strength and stiffness. In fact, with higher doses of rhBMP- in PLGA, the stiffness of the new bone was equal to that of intact controls (64 ± 20 N-mm/deg [intact femurs] versus 45 ± 10 N-mm/degree [medium dose in small PLGA], 61 ± 17 N-mm/degree [high dose in small PLGA], and 36 ± 11 N-mm/degree [medium dose in large PLGA]; P 〉 .05). In conclusion, PLGA implanted with rhBMP- effectively aided in healing large segmental defects in rat femurs. © 1994 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 10 (1976), S. 637-648 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this investigation was to apply the techniques of fracture mechanics to a study of fatigue crack propagation in compact bone. Small cracks parallel to the long axis of the bone were initiated in standardized specimens of bovine bone. Crack growth was achieved by cyclically loading these specimens. The rate of crack growth was determined from measurements of crack length versus cycles of loading. The stress intensity factor at the tip of the crack was calculated from knowledge of the applied load, the crack length, and the specimen geometry. A strong correlation was found between the exprimentally determined crack growth rate and the applied stress intensity. The relationship takes the form of a power law similar to that for other materials. Visual observation and scanning electron microscopy revealed that crack propagation occurred by initiation of subcritical cracks ahead of the main crack.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 10 (1976), S. 537-544 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Cylindrical specimens of bovine subchondral trabecular bone were tested to uniaxial compressive strain levels of 75% to study energy absorption during pore collapse. Stress-strain curves were characterized by macroscopic yield at about 8% strain followed by a significant horizontal pore collapse regime. Energy absorption occurred largely in this postyield regime. Yield strength and energy absorption capacity were found to increase linearly with specimen apparent density. Microstructural analysis of the deformed specimens verified that the mechanism for energy absorption was primarily fracture and buckling of trabeculae. The results suggest that during fracture, the collapse of trabecular bone (and the consequent absorption of energy) serves to attenuate stresses transmitted through the skeleton and thus protect vital structures such as the brain.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...