ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-904X
    Keywords: bioequivalence ; absorption rate ; Tmax ; absorption process rate ; measurement theory ; inference
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. Peak drug concentration (Cmax) measures the extremity of drug exposure and is a secondary indicator of the extent of absorption after area under the concentration time curve (AUC). Cmax serves as the indicator of absorption rate in bioequivalence (BE) studies in the US (1). The use of Cmax, not the time to Cmax(Tmax), as the metric to assess absorption rate causes erratic inferences in BE studies, and incorrect conclusions for some. We can improve BE efficiency (i.e., get the answer right the first time), by properly analyzing the time to Cmax(Tmax) instead of Cmax. Methods. We have previously redirected attention to Tmax as the unconfounded absorption rate variable, instead of Cmax, and have called for equally spaced sampling times during the suspected absorption phase to improve the performance of the rate metric (2). Equal spacing converts Tmax easily into a count variable and we illustrated an appropriate statistical analysis for counts. This paper provides some measurement theory concepts to help judge which is the more appropriate analysis, and also provides parametric confidence limits for Tmax treatment differences. Three separate BE studies are then analyzed by both methods. Results. By focusing on the differences in conclusions, or inferences, this paper identifies three major issues with the current FDA "recommended” analysis of BE studies. First, Cmax, a continuous variable peak-height or extent measure has usurped Tmax's function and performs erratically as a substitute measure for the rate of absorption. Second, Tmax, should be analyzed as a discrete attribute, not as a continuous variable. Third, since several extent measures (AUC, Cmax), not one, are actually being analyzed, an adjustment for multiple testing is mandatory if we are to maintain the size of the test at the desired α level (13), and not inadvertently use a narrower bioequivalence window than is intended. These actions all can have serious unintended consequences on inferences, including making inappropriate ones.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 62 (1996), S. 375-384 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Glass fibers have been treated with γ-aminopropyl-triethoxysilane (APES) through different silanizating procedures, which include APES aqueous solutions and APES vapor adsorption. Transmission Fourier transform IR (FTIR) measurements have been performed on the silanized samples to characterize the silanization reaction. Dansyl-sulfonamide conjugates have then been formed by reaction of dansyl chloride in dimethylformamide solution with the amine functionality's immobilized on the glass fiber surface. Steady-state and time-resolved fluorescence measurements have been performed on dansylated samples. A dependence of the fluorescence intensity and the wavelength of the maximum emission on the silanization procedure has been observed. Good fits of the fluorescence decays of dansyl labels are found when biexponential functions are used for deconvolution, whereas the decay of dansylamides in fluid solution is single exponential. A two-state model for the solid solvent relaxation seems to apply for this samples. Several surface structural changes produced by the different silanization methods have been proposed. FTIR results support the conclusions drawn from fluorescence measurements. © 1996 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...