ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • bioequivalence  (2)
  • Chemistry  (1)
  • discrete count variable  (1)
  • measurement theory  (1)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    ISSN: 1573-904X
    Schlagwort(e): bioequivalence ; absorption rate ; Tmax ; discrete count variable ; Poisson distribution
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Purpose. While peak drug concentration (Cmax) is recognized to be contaminated by the extent of absorption, it has long served as the indicator of change in absorption rate in bioequivalence studies. This concentration measure per se is a measure of extreme drug exposure, not absorption rate. This paper redirects attention to Tmax as the absorption rate variable. Methods. We show that the time to peak measure (Tmax), if obtained from equally spaced sampling times during the suspected absorption phase, defines a count process which encapsulates the rate of absorption. Furthermore such count data appear to follow the single parameter Poisson distribution which characterizes the rate of many a discrete process, and which therefore supplies the proper theoretical basis to compare two or more formulations for differences in the rate of absorption. This paper urges limiting the use of peak height measures based on Cmax to evaluate only for dose-dumping, a legitimate safety concern with, any formulation. These principles and techniques are illustrated by a bioequivalence study in which two test suspensions are compared to a reference formulation. Results. Appropriate statistical evaluation of absorption rate via Tmax supports bioequivalence, whereas the customary analysis with Cmax leads to rejection of bioequivalence. This suggests that the inappropriate use of Cmax as a surrogate metric for absorption rate contributes to the unpredictable and uncertain outcome in bioequivalence evaluation today.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-904X
    Schlagwort(e): bioequivalence ; absorption rate ; Tmax ; absorption process rate ; measurement theory ; inference
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Purpose. Peak drug concentration (Cmax) measures the extremity of drug exposure and is a secondary indicator of the extent of absorption after area under the concentration time curve (AUC). Cmax serves as the indicator of absorption rate in bioequivalence (BE) studies in the US (1). The use of Cmax, not the time to Cmax(Tmax), as the metric to assess absorption rate causes erratic inferences in BE studies, and incorrect conclusions for some. We can improve BE efficiency (i.e., get the answer right the first time), by properly analyzing the time to Cmax(Tmax) instead of Cmax. Methods. We have previously redirected attention to Tmax as the unconfounded absorption rate variable, instead of Cmax, and have called for equally spaced sampling times during the suspected absorption phase to improve the performance of the rate metric (2). Equal spacing converts Tmax easily into a count variable and we illustrated an appropriate statistical analysis for counts. This paper provides some measurement theory concepts to help judge which is the more appropriate analysis, and also provides parametric confidence limits for Tmax treatment differences. Three separate BE studies are then analyzed by both methods. Results. By focusing on the differences in conclusions, or inferences, this paper identifies three major issues with the current FDA "recommended” analysis of BE studies. First, Cmax, a continuous variable peak-height or extent measure has usurped Tmax's function and performs erratically as a substitute measure for the rate of absorption. Second, Tmax, should be analyzed as a discrete attribute, not as a continuous variable. Third, since several extent measures (AUC, Cmax), not one, are actually being analyzed, an adjustment for multiple testing is mandatory if we are to maintain the size of the test at the desired α level (13), and not inadvertently use a narrower bioequivalence window than is intended. These actions all can have serious unintended consequences on inferences, including making inappropriate ones.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 62 (1996), S. 375-384 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: Glass fibers have been treated with γ-aminopropyl-triethoxysilane (APES) through different silanizating procedures, which include APES aqueous solutions and APES vapor adsorption. Transmission Fourier transform IR (FTIR) measurements have been performed on the silanized samples to characterize the silanization reaction. Dansyl-sulfonamide conjugates have then been formed by reaction of dansyl chloride in dimethylformamide solution with the amine functionality's immobilized on the glass fiber surface. Steady-state and time-resolved fluorescence measurements have been performed on dansylated samples. A dependence of the fluorescence intensity and the wavelength of the maximum emission on the silanization procedure has been observed. Good fits of the fluorescence decays of dansyl labels are found when biexponential functions are used for deconvolution, whereas the decay of dansylamides in fluid solution is single exponential. A two-state model for the solid solvent relaxation seems to apply for this samples. Several surface structural changes produced by the different silanization methods have been proposed. FTIR results support the conclusions drawn from fluorescence measurements. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...