ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 1005-1009 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A capillary gas chromatography/mass spectrometry (GC/MS) method for the quantitative analysis of arecoline in plasma has been developed for concentrations in the range 1-50 ng ml-1. Hexadeuterated arecoline was utilized as the internal standard. The removal of drug from plasma was accomplished by a two-step liquid/liquid extraction procedure involving a wash step followed by extraction with 5% triethyl amine in ethyl acetate. The GC/MS determinations were carried out with temperature-programmed capillary GC and ammonia chemical ionization mass spectrometry. The [M + H]+ ions of both analyte and internal standard were monitored at m/z 156 and 162, respectively. The method is linear and has sufficient sensitivity, precision, accuracy and selectivity for analysis of drug levels in human plasma.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analytical method has been developed and validated for the quantitative determination of the N-methyl-D-aspartate (NMDA) antagonist cis-4-phosphonomethyl-2-piperidine carboxylic acid (CGS 19755) in human plasma. It is a member of a new class of compounds with the potential to be neuroprotective and attenuate neuronal damage resulting from brain trauma caused by stroke and head trauma. The method is based on gas chromatography/mass spectrometry and uses stable-isotope labeled CGS 19755 as the internal standard. Samples (1 ml) were first acidified (pH 2), then extracted using a solid-phase aminopropyl ion exchange column. The drug was eluted with NH4OH and evaporated until dry. Extracts were derivatized with a mixture of pentafluoropropionic anhydride and pentafluoropropanol, and analyzed by gas chromatography/mass spectrometry. Separation was accomplished on a DB-225 capillary column (15 m × 0.32 mm) with a 0.25 μ film thickness. Mass spectrometry was carried out under negative ion ammonia chemical ionization conditions with selected ion monitoring at m/z 760 and 764 for derivatized CGS 19755 and the internal standard, respectively. Specificity was shown by the lack of interfering peaks at the retention time of CGS 19755 and internal standard. Recovery and reproducibility assessments show good accuracy, precision and linearity over the validated concentration range of 2-5000 ng ml-1.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analytical method has been developed for the simultaneous determination of a novel orally active angiotensin-converting enzyme inhibitor (CGS 16617) and a stable isotope-labeled analog. Both compounds are isolated from human plasma using an ion-exchange column, derivatized with pentafluoropropionic anhydride and pentafluoropropanol, and analyzed by gas chromatography/mass spectrometry. After splitless injection on a methyl-silicon column, the compound is detected using negative ion chemical ionization with nitrous oxide as a reagent gas. CGS 16617 labeled with four deuteriums and two 13C is used as an internal standard. The accuracy and precision of the method, expressed as the overall mean ± SD recovery obtained from two sets of 36 quality-control samples used during a clinical study (concentration range 0.2-100 ng ml-1 plasma), was 96.1 ± 16.2% for unlabeled drug and 97.6 ± 14.4% for the D4-labeled drug (concentration range 0.2-100 ng ml-1 plasma). The limit of quantification using 1 ml plasma is 0.2 ng ml-1 for both labeled and unlabeled drug.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: Rare-earth doped ions in polar II-VI semiconductors have recently played an important role in the optical properties of materials and devices. In this study, undoped ZnSe and erbium doped ZnSe films were grown by radio frequency (RF) magnetron sputtering method. Atomic Force Microscopy (AFM) was used together with optical microscopy and UV-Vis spectroscopy to characterize the films. Doped samples were found to have higher surface roughness and quite different surface morphology compared to that of undoped samples. The grown films generally show a relatively smooth and uniform surface indicating that they are of overall good quality. The impact of plasma etching on ZnSe:Er film examined under AFM is also discussed.
    Keywords: Solid-State Physics
    Type: NASA University Research Centers Technical Advances in Aeronautics, Space Sciences and Technology, Earth Systems Sciences, Global Hydrology, and Education; 2 and 3; 101-106; NONP-NASA-CD-1999011585
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...