ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 11-16 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The poly(tetra peptide), H- (L·Val1-L·Pro2-Gly3-Gly4)n-L·Val-OMe, which is a recurring sequence in tropoelastin the precursor protein of the elastic fiber, has been irradiation crosslinked to produce an elastomeric material with limited strength. When a material such as a Dacron fabric is impregnated by the coacervate phase of the poly(tetra peptide) prior to irradiation crosslinking at 50 Mrad, the crosslinked product exhibits stress-strain curves with good elastomeric properties and high strength. In addition to the stress-strain curves, the material is characterized by scanning electron microscopy.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Calcification is the principal cause of the clinical failures of the bioprosthetic heart valves fabricated from glutaraldehyde pretreated porcine aortic valves or bovine pericardium. In this paper, we compared the calcification on various types of bovine pericardiums pretreated with two hydrophilic epoxy compounds adding GA post-treatment (EP 1 and EP 2), glutaraldehyde (GA)- and nontreated pericardium (Fresh), respectively, by in vitro and in vivo tests. Significant decrease of calcification was found by pretreatment with both epoxy compounds rather than with glutaraldehyde : 0.250 ± 0.001 (Fresh), 0.276 ± 0.058 (EP l), 0.302 ± 0.071 (EP 2), and 0.478 ± 0.172 (GA) μg (Ca)/mg (dried tissue), respectively, after 20 days dipping in a simulating serum solution in vitro; 115.13 ± 60.11 (Fresh), 129.84 ± 51.08 (EP 1), 167.39 ± 20.81 (EP 2), and 205.19 ± 16.86 (GA) pg/mg, respectively, after 3 months subcutaneous implantation i n rabbits. The in uifro method for evaluating calcification designed by us gave the similar order among four samples with that obtained by in uiuo test. Because the bovine pericardium pretreated with the epoxy compounds adding GA post treatment possesses the greater tenacity than that pretreated only with epoxy compounds or GA, meanwhile the calcification is also significantly decreased with this pretreatment, it may be expected that the bovine pericardium with this pretreatment will have the greater anticalcification and durability in dynamic stress. © 1992 John Wiley & Sons, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...