ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • EARTH RESOURCES AND REMOTE SENSING  (2)
  • Electron capture detector  (2)
  • Capillary columns, 100 μm I.D.  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 697-699 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns, 100 μm I.D. ; On-column injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 427-430 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Electron capture detector ; Cell design ; Time constant, purge flow ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison of the effects on peak shape is made between a 350 and 100 microliter displaced coaxial and a 350 microliter concentric cylinder electron capture cell. Peaks as fast as W1/2 = 0.5 second were detected using electronics operating in the constant current mode. The measured peak shapes are compared to those obtained by computer simulation assuming either complete mixing or plug-like flow within ECD cell. The advantage of controlling the flow pattern through the cell to obtain plug-like flow is demonstrated. Differences in peak shape between the displaced coaxial and concentric cylinder cells of the same volume are explained in terms of the electrostatic fields within the cells.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 651-654 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Electron capture detector ; Cell design ; Hydrogen carrier gas ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new design for an electron capture detector cell is described. The cell is compatible with the requirements of high resolution capillary columns and is shown to be useful in applications that require high analysis speed. A unique method of sample introduction reduces the problems of sample loss by adsorption on the surfaces of the cell. Previously reported problems of sample loss by adsorption on active surfaces within the cell when using hydrogen carrier gas are shown to have been eliminated. Examples are shown demonstrating the increased speed of analysis that can be obtained when using hydrogen carrier gas and 100 micron diameter columns.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-01-25
    Description: Extrapolation of impact cratering rates derived from Canada and Europe suggests that in the cratonic regions of Australia, India, Africa, and Brazil, 14-15 impact craters 20 km diameter should have formed during the last 120 my, and survived erosional erasure. In fact, in these areas, only 2 craters are known that approximately qualify: (1) Gosses Bluff, 22 km, 130 + or - 6 my old, and; Strangways, 24 km and 150 + or - 70 my old. It is therefore likely that about a dozen relatively large and preserved impact craters await discovery in these less explored cratons. A larger number of younger and smaller craters must also exist. An informal search is reported for impact craters using photographs obtained by Shuttle astronauts. Photographs taken with the 250 mm lens on Hassalblad cameras have a resolution of 25 m and cover a nominal area of 50x60 sq km. A larger format Linhof camera with similar resolution but 4 times larger area was flown March 1984, and will fly again in the future. Shuttle imagery has numerous advantages in looking for impact craters and for other types of Earth observations.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: Lunar and Planetary Institute The 47th Ann. Meteoritical Soc. Meeting; 1 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-12
    Description: Remote sensing with the Landsat Thematic Mapper of debris avalanche deposits in the Central Andes between 18 and 27 deg S revealed, for the first time, the presence of 28 breached volcanic cones and 11 major volcanic debris avalanche deposits, several of which cover areas in excess of 100 sq km. It is concluded that such avalanche deposits are normal products of the evolution of large composite volcanoes, comparable with lava and pyroclastic flow deposits. A statistical survey of 578 composite volcanoes in the same area indicated that a majority of cones which achieve edifice heights between 2000 and 3000 m may undergo sector collapse. The paper describes morphological criteria for identifying breached composite cones and volcanic debris avalanches using orbital images.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: Bulletin of Volcanology (ISSN 0258-8988); 50; 258-278
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...